Overview
Reliability and Stability of the L5S UV-Visible Spectrophotometer with professional proportional monitoring dual beam of light path system and low noise circuit design. The instrument can meet a wide range of needs from daily analysis to scientific research.
Features
1. Adopt 8-inch color touch LCD display, providing flexible and convenient operation.
2. Adopt proportional monitoring dual beam of light path structure, configure high-performance "Holographic grating" monochromator, with low stray light, high resolution, outstanding Optical inspection accuracy, measurement accuracy, reproducibility and Stability.
3. With unique automatic adjustment "0" and adjustment "100%" functions, as well as automatic 8-pool Colorimetric dish holder.
4. With full-band scanning (limited to S type), sub-band scanning (limited to S type), dynamic time scanning, GOTO lambda, linear regression, concentration direct reading, peak and valley detection and other advanced functions.
5. Optional thermal plotter for data printing, Light spectrum scanning (limited to S type), fixed wavelength time scanning, linear regression and other Linear dispersion drawing.
6. Equipped with USB interface, it can interact with PC, and realize data processing, graph scanning, mass storage and secondary development through optional software.
7. Equipped with professional power-off protection measures, it can memorize test data, scan patterns, regression equations, and instrument correction values, and achieve fast startup initialization.
8. Using high-energy long-life flange to locate deuterium lamps and imported tungsten lamps, there is no need for cumbersome optical path adjustment when replacing deuterium lamps.
Principle
The instrument works based on a proportional monitoring dual beam of light optical path system. After the light emitted by the light source is split by the monochromator, it is divided into two beams, one beam passes through the sample and the other beam is used as a reference. The two beams are received and compared by the Detector to accurately measure the absorption of specific wavelengths of light in the sample, and then analyze the composition and concentration of the sample.
Applications
Daily analysis, scientific research
Steps
1. Boot initialization.
2. Set parameters such as wavelength through the touch screen.
3. Use the automatic "0" and "100%" functions to calibrate.
4. Put in the sample and reference, and start the measurement.
5. Select scanning, dynamics, concentration direct reading and other functions as needed for testing.
6. Connect to the PC through the USB interface for data transfer or use optional software to process data.
Notice
• Power supply voltage must be AC220V +/- 22V, frequency 50Hz +/- 1Hz.
• The rated power is 200W, please ensure stable power supply.
• When replacing the deuterium lamp, pay attention to the operation specifications, and uninstall the flange positioning screws to avoid touching the light path.
• The instrument is equipped with a 1cm Colorimetric dish rack as standard, and a Miscellaneous Colorimetric dish rack can be selected as required.
• Optional thermal graphics printer or UVwin8 ultraviolet spectroscopy software can be expanded.
• Pay attention to the operating environment of the instrument to keep its performance stable.