Overview
The BANTE S10 is a high-performance wireless Bluetooth pH Meter for Android smartphones or tablets. It supports 1 to 5 point calibrating and can customize 14 functional parameters. Measurement accuracy up to 0.002pH is suitable for pH, mV and temperature measurement of aqueous solutions.
Features
1. High performance Bluetooth pH Meter, suitable for measurement of pH, mV and temperature of aqueous solution.
2.1 to 5 point calibrated, automatically recognizes USA/NIST/DIN standard buffer.
3. Solution temperature coefficient, compensates for pure water measurement and converts reading to 25 ° C.
4. Automatic temperature compensation to ensure accurate measurement of the full range.
5. Automatic end point locking, maintaining stable readings for easy browsing and recording.
6. Timed interval readings, sending measurement data to memory or printer.
7. Limit alarm, automatic warning Measured value exceeds the set range.
8. Calibrate expiration reminder, prompting the user to calibrate the meter regularly.
9. calibrate report showing date, time, pH slope and zero offset.
10. Password protection against unauthorized calibrating with settings.
11. Multi-Parameter measurement, can connect Bluetooth conductivity and dissolved oxygen meter to the device and display Measured value.
12. Reset function, automatically restore the meter to the factory default settings.
Principle
The pH Meter connects to Android devices via Bluetooth 4.0 or higher for wireless data transfer. It uses automatic temperature compensation technology to ensure accurate measurement of pH and mV values in the range of 0 to 100 ° C, and supports automatic end point locking and timed interval readings to improve measurement Stability and data logging efficiency.
Applications
Aqueous solution pH measurement, mV measurement, temperature measurement, water quality analysis, laboratory testing, environment monitoring
Steps
1. Turn on the meter and ensure that Bluetooth is connected to the Android device.
2. Select the calibrated point (1 to 5 points), the meter automatically recognizes the standard buffer.
3. Measurement parameters such as temperature compensation and reading mode.
4. Immerse Electrode in the solution to be tested, and the meter automatically displays pH, mV, or temperature values.
5. Use the automatic endpoint lock function to stabilize readings, or set timed intervals to record data.
6. Transfer data to memory or printer, check calibrated report if necessary.
Notice
• Regularly calibrate meters to maintain accuracy, and calibrate reminders can be set for 1 to 99 days.
• Use password protection to prevent unauthorized settings changes.
• Ensure that the Bluetooth transmission distance does not exceed 10 meters to avoid signal interruption.
• Use 1.2V lithium battery or AAA battery power supply, and replace the battery in time.
• Perform measurements under stable conditions (Fast, Standard or High Accuracy mode) for accurate results.