Overview
The IPRE IPRE-Y Benchtop is a multifunctional industrial endoscope device with viewing directions of 0 °, 30 °, 70 ° and 90 °. Optical inspection focal length can be continuously adjusted. The device is equipped with a cold Illuminant system, the luminance can be adjusted in multiple stages, and it uses Portable Illuminant and optical fiber light transmission lighting technology.
Features
1. Provide four viewing directions of 0 °, 30 °, 70 °, and 90 °
2. Optical inspection focal length can be adjusted continuously
3. Multi-level adjustment of luminance
4. The mirror body can be continuously rotated 360 ° axially for observation
5. Integrated CCD image processing system, support photography and video recording
6. Equipped with a 7-inch display screen and 8G TF card storage
7. Support built-in rechargeable lithium battery and AC 220V power supply dual power supply mode
8. Portable Illuminant Design
9. Fiber optic lighting system
Principle
The IPRE-Y Benchtop direct mirror transmits cold Illuminant rays of light through optical fibers, uses Optical inspection lens system to collect images, integrates CCD to convert Optical inspection images into electrical signals, and realizes observation, photography and video recording through image processing system. The mirror body can be rotated 360 ° axially to achieve all-round observation.
Applications
Industrial inspection, equipment maintenance, pipeline inspection, machinery manufacturing, mass inspection
Standards
The product information does not mention the specific standards met
Steps
1. Select the appropriate viewing direction and Probe diameter
2. Adjust Optical inspection focal length to clear state
3. Adjust Illuminant luminance level as needed
4. All-round observation by rotating the mirror body 360 °
5. Use photography or video recording to record test results
6. Export storage data through USB interface
7. Clean the equipment in time after the work is completed
Notice
• Ambient Temperature should be kept in the range of -20 ℃ to 60 ℃
• relative humidity should be controlled between 10% and 85%
• The equipment allows oil stains and can withstand 5% acid and alkali environments
• After the work is completed, the surface of the equipment should be wiped in time
• Pay attention to the correct use of built-in battery or AC power supply
• The storage medium is 8G TF card to ensure sufficient storage space