Overview
TBJ-X4 + RDS 44 #3/8 'Automatic Film Applicator is a vacuum heated Film Applicator designed for applications such as polyimide film Spreader 100 μm Pressure sensitive adhesive. The equipment adopts imported accessories, the temperature can reach 200 ° C, and the standard film bar with accuracy up to 1 μm ensures the uniform and smooth Spreader by controlling the speed and stable pressure. It is suitable for corporate R & D institutions and university scientific research fields.
Features
1. Using imported accessories, reliable performance.
2. With vacuum heating function, Heating Temperature range RT +~ 200 ℃.
3. Standard High Accuracy film bar, China bar accuracy up to 1μm, and contains an imported RDS 44 rod.
4. Spreader speed digital display, support 5~ 180mm/s stepless speed (< 5mm/s can be customized).
5. Equipped with 400 * 300mm Vacuum chuck, uniform adsorption.
6. Optional accessories and customization functions, such as substrate fixture, UV curing device, etc.
Principle
The Automatic Film Applicator uses a Vacuum chuck to fix the substrate flat on the heating table, and the heating system warms the Spreader area to a set temperature (up to 200 ° C) to melt the material. When the Spreader is used, the film bar is driven by the motor to move at a set precise speed, and the glue or paint is evenly applied to the surface of the substrate under stable pressure, thereby ensuring the uniformity and conformity of the coating.
Applications
Experiment and Research on Material Spreader in R & D Institutions of Multinational Enterprises, Universities and Research Institutions at Home and Abroad
Standards
The data did not mention specific compliance criteria
Steps
1. Prepare the substrate and place it on the Vacuum chuck table.
2. Turn on the vacuum pump, adsorption fixed substrate.
3. Set the required heating temperature and start heating.
4. Select the appropriate film bar and install it.
5. Set parameters such as Spreader speed.
6. Start the Spreader program to complete the automatic film.
7. After the Spreader is completed, turn off the device and remove the sample.
Notice
The power supply of the device is 220V 50Hz, please ensure that the power supply matches.
* Please check whether the Vacuum chuck and heating function are normal before operation.
* According to the uneven thickness of the substrate, optional Accessories such as weight and silicone pad can be used.
Customized features (e.g. jet system, UV curing device) need to be confirmed in advance.
* Customized when coating speed is less than 5mm/s.
* Temperature range and uniformity (+/- 3 ° C).