Overview
TENLIN DC-0506 Vertical Low Temperature Circulating Bath is a precision thermostatic device with a Temperature range of -5~ 100 ° C and a Tank volume of 7.5L. It uses self-developed temperature control technology, with High Accuracy, High Stability and multiple Safety protection functions, suitable for a variety of experiments and test scenarios that require precise temperature control.
Features
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system can correct the display and actual temperature errors to ensure accurate display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection, over-temperature alarm function, can set the alarm temperature and automatically cut off the load.
5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to ensure greater use space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Use Software Digital Lock Control system settings to prevent misoperation.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube.
11. Support non-standard customization.
Principle
The device monitors the medium temperature in the tank in real time through the High Accuracy PT100 Sensor, and feeds the signal back to the microprocessor Control system. According to the difference between the set temperature and the measured temperature, the system automatically adjusts the working status of the heater and the fully enclosed Compressor refrigeration system through the intelligent PID algorithm to achieve accurate and stable control of the medium temperature in the tank. The standard internal and external circulation pumps can export the thermostatic medium to provide a static thermostatic environment for external equipment.
Applications
Application is not explicitly mentioned in the information provided.
Standards
The compliance criteria are not explicitly mentioned in the information provided.
Steps
The steps are not explicitly mentioned in the information provided.
Notice