Please contact customer service
Temperature range -40~ 100 ℃, Temperature Fluctuation +/- 0.03 ℃, with High Accuracy PID temperature control, over-temperature protection alarm, timing function and internal and external circulation, hidden coil design to increase the use of space in the slot.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB035934
Service :The delivery and service By NBCLab.Com
The TENLIN DC-4006 Vertical Low Temperature Circulating Bath is a precision thermostatic device with a Temperature range of -40~ 100 ° C and a Tank volume of 7.5L. It adopts self-developed temperature control technology, featuring High Accuracy and High Stability, and comes standard with internal and external circulation functions to meet the experimental needs of users in different scenarios.
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components. 2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display. 3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃. 4. With over-temperature protection, over-temperature alarm function, can set the alarm temperature and automatically cut off the load. 5. With timing function, the total working time of the equipment can be set, and the load can be automatically cut off at that time. 6. Adopt hidden chilled down coil design to ensure larger space in the groove. 7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment. 8. Use Software Digital Lock Control system settings to prevent misoperation. 9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent. 10. Standard internal and external circulation function, external circulation import and export outer diameter is 10mm round tube. 11. Support non-standard customization.
The device monitors the medium temperature in the tank in real time through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the heating and refrigeration power (provided by the fully enclosed Compressor refrigeration system) to accurately maintain the set temperature. At the same time, the internal and external circulation pumps (Flow rate 6L/min) promote the temperature uniformity of the medium in the tank and the external circulation pipeline to achieve fast and stable thermostatic control.
Laboratory thermostatic experiments, sample reaction thermostatic, material testing, Viscometer calibrating, Rotary evaporator matching, Miscellaneous scientific research and industrial fields requiring precision temperature control
The data did not mention specific compliance criteria
1. Add an appropriate amount of suitable medium to the Tank. 2. Turn on the power supply and turn on the power switch of the device. 3. Set the required temperature, timing duration and over-temperature alarm temperature and other parameters through the control panel. 4. Start the device, and the device starts to automatically control the temperature. 5. If external circulation is required, start the circulation pump after connecting the external pipeline. 6. After the experiment, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
• Before use, please ensure that the medium liquid level in the tank is appropriate to avoid dry burning or overflow. Equipment should be placed on a well-ventilated and stable countertop. • When setting the over-temperature alarm temperature, it should be higher than the Operating temperature but lower than the boiling point of the medium or the maximum allowable limit of the equipment. • Regularly check and clean equipment to ensure good heat dissipation. • Non-professionals should not disassemble or modify the internal parameter settings of the device without authorization. • When moving or not in use for a long time, please empty the medium in the tank and keep it safe.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.