Overview
TENLIN DC-0510 Vertical Low Temperature Circulating Bath is a precision thermostatic device with a Temperature range of -5~ 100 ° C and a Tank volume of 10L. The device adopts self-developed temperature control technology, with High Accuracy Temperature Control and stable performance, suitable for various experimental scenarios that require precise temperature control.
Features
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection, over-temperature alarm function, can set the alarm temperature and automatically cut off the load.
5. With timing function, the total working time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to ensure larger space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Use software to digitally lock Control system settings to avoid misoperation.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation import and export for the outer diameter of 10mm round tube.
11. Support non-standard customization.
Principle
The device detects the temperature of the medium in the tank through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically adjust the Power output of the heating or cooling system (fully enclosed Compressor) according to the difference between the set temperature and the measured temperature to achieve fast and accurate temperature control. Standard internal and external circulation pumps promote uniform temperature of the medium in the tank and external circulation lines.
Applications
Chemical synthesis, biological fostering, physical experiments, material testing, Measurement calibrating, Petrochemicals, pharmaceutical R & D, Universities & colleges, research institutes
Standards
The data did not mention specific compliance criteria.
Steps
The information does not provide specific operation steps.
Notice
Please read the instructions carefully before use.
● Ensure that the equipment is placed in a smooth, well-ventilated environment.
When adding the medium, the liquid level shall not exceed the maximum allowable range.
● When making external circulation connections, make sure that the pipeline connections are firm and leak-free.
● When the equipment is running, do not block the entry and exit trends.
When setting the over-temperature alarm temperature, a reasonable safety value should be set.
● Non-professionals should not modify Control system parameters without authorization.
When the equipment is not used for a long time, the medium in the tank should be emptied and kept drying.