High temperature control accuracy, resolution of 0.01 ℃, Fluctuation +/- 0.03 ℃. With over temperature protection, timing function and internal and external circulation system, intelligent PID temperature control ensures temperature stability, hidden coil design increases the space in the groove.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB035942
Service :The delivery and service By NBCLab.Com
The TENLIN DC-1015 Vertical Low Temperature Circulating Bath is a precision thermostatic device with a Temperature range of -10 ° C to 100 ° C and a Tank volume of 15 liters. It uses self-developed temperature control technology, equipped with High Accuracy Sensor and imported electronic components, which can achieve high resolution, high stability temperature control, and has internal and external circulation functions to meet the needs of a variety of experimental scenarios.
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components. 2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display. 3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃. 4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off. 5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time. 6. Adopt hidden chilled down coil design to increase the effective use space in the groove. 7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment. 8. Use software digital lock Control system settings to prevent misoperation and ensure accurate data. 9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent. 10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube. 11. Support non-standard customization.
The device monitors the temperature of the medium in the Tank in real time through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the Power output of the heating and cooling system (fully enclosed Compressor) according to the difference between the set temperature and the measured temperature, resulting in fast and accurate temperature control. Standard internal and external circulation pumps circulate the thermostatic medium to external devices for extended Temperature range.
Laboratory thermostatic experiments, sample reaction thermostatic, material testing, biological foster, Viscometer calibrating, Rotary evaporator matching, Miscellaneous Research and industrial fields requiring High Accuracy thermostatic environment
The data did not mention specific compliance criteria
1. Place the device in a smooth and ventilated place and connect it to the power supply. 2. Inject an appropriate amount of thermostatic medium into the Tank. 3. Turn on the power switch and set the required temperature, over-temperature alarm temperature and timing duration through the control panel. 4. Start the equipment, the system starts to work, and the Compressor and heating system run automatically according to the PID control. 5. After the temperature reaches the set value and stabilizes, the experimental operation can be carried out, or the external circulation pipeline can be connected. 6. After the experiment, turn off the power of the equipment and drain or properly dispose of the medium in the tank.
● Please use the equipment in a stable and well-ventilated environment. ● Please inject the appropriate type and sufficient amount of thermostatic medium into the tank according to the experimental temperature requirements before use. Do not start the heating or cooling function when there is no medium in the tank or the medium liquid level is too low. When setting the over-temperature alarm temperature, it should be set within a safe range to prevent accidents. ● When performing external circulation operations, please ensure that the pipeline connection is firm and there is no leakage. ● When the equipment is running, do not block the entry and exit trends to ensure good heat dissipation. Before cleaning and maintenance, be sure to disconnect the power supply of the equipment. Non-professionals should not disassemble or modify the internal parameter settings of the equipment without authorization.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.