Using self-developed temperature control technology, Temperature resolution up to 0.01 ℃, Fluctuation +/- 0.05 ℃. With over-temperature protection, timing function and hidden chill down coil design, effectively improve the use space in the Tank and experimental safety.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB035946
Service :The delivery and service By NBCLab.Com
The TENLIN DC-0520 is a vertical Low Temperature Circulating Bath with a Temperature range of -5 to 100 ° C and a Tank Volume of 20L. The device uses self-developed temperature control technology with High Accuracy Temperature Control and Stability, suitable for various experiments requiring precise thermostatic environments.
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components. 2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display. 3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃. 4. With over-temperature protection, over-temperature alarm function, can set the alarm temperature and automatically cut off the load. 5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time. 6. Adopt hidden chilled down coil design to increase the effective use space in the groove. 7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment. 8. Software Digital Lock Control system settings to prevent misoperation and ensure that the experimental data is correct. 9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent. 10. Standard internal and external circulation function, external circulation import and export for the outer diameter of 10mm round tube. 11. Support non-standard customization.
The device monitors the temperature of the medium in the Tank in real time through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically adjust the Power output of the heater or Compressor according to the difference between the set temperature and the measured temperature for fast and accurate temperature control. Standard internal and external circulation pumps circulate the thermostatic medium to external devices for extended Temperature range.
Chemical synthesis, bioengineering, pharmaceutical research, material testing, physical experiments, Measurement calibrating
Not mentioned
1. Add an appropriate amount of suitable medium to the Tank. 2. Connect the power supply and turn on the power switch of the device. 3. Set the required temperature value and Working time parameters through the control panel. 4. Start the equipment, the equipment starts working, and automatically heats or cools to achieve and maintain the set temperature. 5. If external circulation is required, start the circulation pump after connecting the external pipeline. 6. After the experiment, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
Please read the instructions carefully before use and ensure that the equipment is properly grounded. ● Please select the appropriate thermostatic medium according to the experimental requirements and ensure that the liquid level is within a safe range. ● When the equipment is running, do not touch high temperature or moving parts such as heaters and Compressors. It is forbidden to start the heating function when there is no medium or insufficient medium in the tank. Before moving or cleaning equipment, always cut off the power and allow it to chill down completely. When the equipment alarms, please identify the cause and troubleshoot before using it. Non-professional personnel should not disassemble or repair the internal parts of the equipment without authorization. ● When not in use for a long time, please empty the medium in the tank and store the equipment in a drying and ventilated place.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.