Please contact customer service
Adopt self-developed temperature control technology, Temperature Fluctuation +/- 0.05 ℃, resolution up to 0.01 ℃. With over-temperature protection and timing function, hidden chill down coil design increases the use space in the groove, supports internal and external circulation to meet the needs of multiple scenarios.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB035947
Service :The delivery and service By NBCLab.Com
The TENLIN DC-1020 Vertical Low Temperature Circulating Bath is a laboratory thermostatic device with a Temperature range of -10 to 100 ° C and a Tank volume of 20L. The device uses self-developed temperature control technology, with High Accuracy temperature control and display functions, and comes standard with an internal and external circulation system to meet the thermostatic needs of users in multiple scenarios.
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components. 2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display. 3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃. 4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off. 5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time. 6. Adopt hidden chilled down coil design to increase the effective use space in the groove. 7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment. 8. Software Digital Lock Control system settings to prevent misoperation and ensure accurate experimental data. 9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent. 10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube. 11. Support non-standard customization.
The device senses the temperature of the medium in the Tank through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the Power output of the heating or cooling system according to the difference between the set temperature and the measured temperature for fast and stable temperature control. The standard circulation pump can carry out domestic circulation or external circulation of the thermostatic medium in the tank to expand the Temperature range.
Laboratory thermostatic experiments, sample thermostatic preservation, chemical reaction thermostatic control, material testing, biological fostering, viscosity measurement, density measurement
Not mentioned
1. Add an appropriate amount of heat transfer medium to the Tank. 2. Power on the device. 3. Set the required target temperature, over-temperature alarm temperature and timing duration through the control panel. 4. Start the equipment, start the equipment, and adjust the temperature of the medium through the Compressor refrigeration or heating element. 5. After the equipment reaches the set temperature and is stable, the experimental operation can be carried out. 6. After the experiment, turn off the power of the device.
Please ensure that the medium level in the Tank is appropriate before use. Do not make unnecessary parameter modifications or misoperation while the equipment is running. ● Pay attention to ventilating the equipment to ensure good heat dissipation. Before moving or cleaning equipment, be sure to disconnect the power supply. ● If you need to connect the external circulation, please ensure that the pipeline connection is firm and there is no leakage. Optional liquid level protection system is available to prevent abnormal liquid level. ● Optional RS485 Communication interface to achieve host computer control. ● Optional multi-point correction function to improve multi-temperature point accuracy. ● Optional external PT100 to achieve precise temperature control of external circulation. Optional brackets are available to place specific containers.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.