Overview
The TENLIN DC-4020 Vertical Low Temperature Circulating Bath is a precision thermostatic device with a Temperature range of -40~ 100 ° C and a Tank Volume of 20L. It uses self-developed temperature control technology, with High Accuracy Temperature Control and Stability performance, suitable for various experiments and tests requiring precise temperature environments.
Features
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection, over-temperature alarm function, can set the alarm temperature and automatically cut off the load.
5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to ensure larger space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Use software to digitally lock Control system settings to avoid misoperation.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation import and export for the outer diameter of 10mm round tube.
11. Support non-standard customization.
Principle
The device monitors the temperature of the medium in the Tank in real time through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the Power output of the heating and cooling system (including the fully enclosed Compressor) according to the difference between the set temperature and the measured temperature, and promotes the uniform temperature of the medium in the tank through the internal and external circulation pumps, so as to achieve fast, accurate and stable temperature control.
Applications
Application is not explicitly mentioned in the information provided.
Standards
The compliance criteria are not explicitly mentioned in the information provided.
Steps
The operation steps are not explicitly mentioned in the information provided.
Notice
Notes are not explicitly mentioned in the information provided.