Please contact customer service
Temperature range -40~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, equipped with large screen LCD display, resolution up to 0.01 ℃, with over temperature protection, timing and internal and external circulation functions, hidden chill down coil design to increase the use of space in the Tank.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB035955
Service :The delivery and service By NBCLab.Com
The TENLIN DC-4030 Vertical Low Temperature Circulating Bath is a thermostatic device with a Temperature range of -40 to 100 ° C and a Tank volume of 30L. It uses self-developed temperature control technology, with High Accuracy Temperature Control and a number of intelligent protection functions, suitable for experimental and production environments that require precise temperature control.
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 and imported electronic components. 2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display. 3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃. 4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off. 5. With timing function, you can set the Operating Time of the device, and automatically cut off the load at that time. 6. Adopt hidden chilled down coil design to increase the use space in the groove. 7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment. 8. Software Digital Lock Control system settings to prevent misoperation. 9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent. 10. Standard internal and external circulation function, external circulation import and export for the outer diameter of 10mm round tube. 11. Support non-standard customization.
The device detects the temperature of the medium in the tank through the High Accuracy PT100 temperature sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the heating and refrigeration power (provided by the fully enclosed Compressor refrigeration system) for fast and stable temperature control. At the same time, the system has the function of internal and external circulation, which can pump out the thermostatic medium and perform thermostatic control on external devices.
Chemical synthesis, biological fostering, material testing, physical experiments, Petrochemicals, pharmaceutical research and development
Not mentioned
1. Place the device in a smooth and ventilated place and connect it to the power supply. 2. Inject an appropriate amount of suitable medium into the Tank. 3. Turn on the power switch and set the required temperature, over-temperature alarm temperature and timing duration through the control panel. 4. Start the equipment and start cooling or heating. 5. After the temperature reaches the set value and stabilizes, the experimental operation can be carried out, or the external circulation pipeline can be connected. 6. After the experiment, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
Equipment should be placed in a stable, well-ventilated environment. Please inject an appropriate amount of suitable medium as required to avoid dry burning or overflow. When setting the over-temperature alarm temperature, it should be set slightly higher than the temperature required for the experiment. ● When using the external circulation function, please ensure that the pipeline connection is firm and there is no leakage. Non-professionals should not change the system lock parameters at will. Regularly clean and maintain the equipment to ensure good heat dissipation. If the liquid level protection system is selected, please pay attention to the liquid level limit to avoid triggering the protection shutdown.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.