Overview
The TENLIN DC-6006 Vertical Ultra Low Temperature Thermostatic Bath is a precision temperature control device with a Temperature range of -60 ° C to 100 ° C and a Tank volume of 7.5L. It uses self-developed temperature control technology, featuring High Accuracy and High Stability. Temperature resolution up to 0.01 ° C and Fluctuation of +/- 0.05 ° C. It is suitable for various experiments and test scenarios that require precise temperature control.
Features
Adopt new self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and all imported electronic components.
2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off.
5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to increase the effective use space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Software Digital Lock Control system settings to prevent misoperation.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube.
11. Support non-standard customization.
Principle
The Thermostatic bath monitors the temperature of the medium in the tank in real time through the High Accuracy PT100 Sensor and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically or manually adjust the Power output of the heating and cooling system (fully enclosed Compressor) according to the deviation of the set temperature and the measured temperature to achieve fast and accurate temperature control. Temperature uniformity of the medium in or outside the tank is ensured by standard internal and external circulation pumps.
Applications
Application is not mentioned in the information provided.
Standards
The compliance criteria are not mentioned in the information provided.
Steps
The operation steps are not mentioned in the information provided.
Notice
Notes are not mentioned in the information provided.