Overview
The TENLIN DC-6015 Vertical Thermostatic bath is a precision thermostatic device with a Temperature range of -60 ° C to 100 ° C and a Tank volume of 15 liters. It uses self-developed temperature control technology with High Accuracy Temperature Control and multiple Safety protection functions, suitable for various experiments and tests requiring precise temperature environments.
Features
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off.
5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to increase the effective use space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Software Digital Lock Control system settings to prevent misoperation and ensure that the experimental data is correct.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube.
11. Support non-standard customization.
Principle
The Thermostatic bath is cooled by a fully enclosed Compressor refrigeration system and uses a self-developed intelligent temperature control software system for precise temperature control. The system monitors the medium temperature in the tank in real time through the High Accuracy PT100 Sensor, and the intelligent PID algorithm automatically adjusts the heating or refrigeration power according to the difference between the set temperature and the measured temperature to achieve fast and stable temperature control, and controls the Temperature Fluctuation within +/- 0.05 ° C.
Applications
This information is not mentioned in the information provided.
Standards
This information is not mentioned in the information provided.