Overview
The TENLIN DC-7020 is a vertical ultra-low temperature Thermostatic bath with a Temperature range of -70 ° C to 100 ° C and a Tank volume of 20L. The equipment uses self-developed temperature control technology, with High Accuracy Temperature Control and Stability, suitable for various experiments and tests requiring ultra-low temperature environments.
Features
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate temperature display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off.
5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to increase the effective use space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Software digital locking function to prevent misoperation and ensure the accuracy of experimental data.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube.
11. Support non-standard customization.
Principle
The equipment achieves rapid cooling through a fully enclosed Compressor refrigeration system. Its intelligent temperature control system uses the High Accuracy PT100 Sensor to detect the temperature, and automatically or manually adjusts the heating and refrigeration power through the PID algorithm to maintain the accurate and stable temperature of the medium in the Tank. The software system calibrates the temperature display to ensure accurate readings. At the same time, through the internal and external circulation pumps, the thermostatic medium in the tank can be exported to provide a thermostatic environment for external equipment.
Applications
This information is not mentioned in the information provided.
Standards
This information is not mentioned in the information provided.
Steps
This information is not mentioned in the information provided.
Notice
This information is not mentioned in the information provided.