Overview
TENLIN DCW-1006 horizontal Low Temperature Circulating Bath is a precision thermostatic device with a Temperature range of -10~ 100 ° C and a Tank volume of 7.5L. It uses advanced control and cooling technology to provide a stable and uniform low temperature thermostatic environment for laboratories.
Features
1. Low Noise Air-Cooled Fully Enclosed Compressor Unit, Fast Cooling Speed and Strong Temperature Stability.
2. Control system adopts self-developed special software and high standard Pt100 Sensor and all imported electronic components.
3, with internal and external circulation system, external circulation can establish a second thermostatic field or as an external cold source, domestic circulation to ensure that the liquid temperature in the tank is uniform and stable.
4. Equipped with a complete protection system, including refrigeration overheating/overcurrent protection, over-temperature sound and light alarm, and automatic load shutting function.
5. Adopting a large liquid crystal control instrument, it is easy to operate and supports P.I.D automatic search or manual adjustment.
6. Temperature correction accuracy up to 0.01 ° C, Temperature Fluctuation up to +/- 0.2 ℃~ +/- 0.05 ° C (depending on the model).
Principle
The device reduces the temperature of the liquid in the tank through the refrigeration system, and is monitored and regulated in real time by the High Accuracy Temperature Control system. The circulatory system (domestic circulation or external circulation) prompts the flow of liquid, ensuring a highly uniform and stable temperature throughout the work area, resulting in accurate thermostatic control.
Applications
Laboratory thermostatic experiment, sample reaction thermostatic, second thermostatic field establishment, external experimental vessel cooling
Steps
1. Place the device in a smooth and ventilated place and connect it to the power supply.
2. Inject an appropriate amount of heat transfer medium (such as silicone oil or water) into the Tank.
3. Turn on the power switch and set the required temperature and parameters (such as the upper and lower limits of the alarm temperature) through the large LCD control panel.
4. Choose domestic circulation or external circulation mode as needed.
5. Start the equipment, the refrigeration and Control system starts to work until it reaches and stabilizes at the set temperature.
6. After use, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
Notice
* Equipment should be placed in a well-ventilated, non-direct sunlight and away from heat sources.
* Before use, please ensure that the liquid level in the Tank is at an appropriate height to avoid dry burning or overflow.
* Do not use flammable, explosive or corrosive media in the tank.
* When setting the over-temperature alarm temperature, it should be set within a safe and reasonable range.
* When the device is running, do not block the entry and exit trends to ensure normal heat dissipation.
Before performing maintenance or cleaning, be sure to cut off the power supply.
* If not used for a long time, please empty the liquid tank and keep the equipment drying.