Overview
The TENLIN DCW-1010 horizontal Low Temperature Circulating Bath is a precision temperature control device with a Temperature range of -10 ° C to 100 ° C. It features a horizontal design with a Tank volume of 10L and an internal and external circulation system to provide a uniform and stable temperature field. It is suitable for various experiments and tests that require precise temperature control.
Features
1. Low Noise Air-Cooled Fully Enclosed Compressor Unit, Fast Cooling Speed and Strong Temperature Stability.
2. Control system adopts self-developed special software and High Accuracy Pt100 Sensor, with imported electronic components, accurate temperature control.
3, with internal and external circulation system, external circulation can establish a second thermostatic field or as an external cold source, domestic circulation to ensure that the liquid temperature in the tank is highly uniform and stable.
4. Equipped with a complete protection system, including Compressor overheating and overcurrent protection, as well as Control system over-temperature alarm and automatic load cutting function.
5. Adopting a large liquid crystal control instrument, it is easy to operate and supports automatic search or manual adjustment of P.I.D. parameters.
6. Temperature correction accuracy up to 0.01 ° C, Temperature Fluctuation up to +/- 0.03 ° C.
Principle
The device cools or heats the medium inside the Tank through a refrigeration system (fully enclosed Compressor unit) and a heating system. The Control system monitors the temperature in real time through the High Accuracy Pt100 Sensor and precisely adjusts the refrigeration or Heating power using the P.I.D algorithm to achieve a fast reach of the set temperature and maintain stability. The circulation system (domestic circulation or external circulation) ensures Temperature uniformity of the connected system inside or outside the Tank.
Applications
Experiment, testing and production in the fields of bioengineering, medicine, chemical industry, physics, materials, Measurement, Universities & colleges, research institutes, etc.
Standards
The data did not mention specific compliance criteria.
Steps
1. Inject an appropriate amount of suitable medium into the Tank.
2. Connect the device power supply.
3. Set the required temperature and parameters (e.g. alarm temperature limit) through the large LCD control panel.
4. Choose domestic circulation or external circulation mode as needed.
5. Start the device and start working.
6. After use, turn off the power supply of the equipment and maintain it properly.
Notice
Please use a power supply that meets the requirements and ensure good grounding.
* The injected medium needs to be appropriate and ensure that its freezing point is lower than the minimum Operating temperature of the equipment.
* During the operation of the equipment, do not block the entry and exit trends to ensure good ventilation.
* When making external circulation connections, please ensure that the pipeline connections are firm and leak-free.
* When the over-temperature alarm is triggered, please check and troubleshoot in time.
Before cleaning the equipment, be sure to disconnect the power supply.
Non-professionals should not disassemble or repair the equipment themselves.