Overview
The TENLIN HX-2008 cryogenic thermostatic circulator is a precision temperature control device with a Temperature range of -20 ° C to 100 ° C and a Tank volume of 8L. The device is cooled by an Air-Cooled fully enclosed Compressor and is equipped with an internal and external circulation system to provide a stable and uniform thermostatic environment for the laboratory or as an external cold source.
Features
1. Low Noise Air-Cooled Fully Enclosed Compressor Unit, Fast Cooling Speed and Strong Temperature Stability.
2. Control system adopts self-developed special software and High Accuracy Pt100 Sensor, with imported electronic components, accurate temperature control.
3, with internal and external circulation system, external circulation can establish a second thermostatic field or as a cold source to cool the external experimental vessel, domestic circulation to ensure that the liquid temperature in the tank is highly uniform and stable.
4, with multiple Safety protection system, including Compressor overheating, overcurrent protection, and over-temperature sound and light alarm, over-temperature automatic load cutting and other functions.
5. Equipped with a large LCD control instrument, it is easy to operate and supports automatic search or manual adjustment of P.I.D. parameters.
6. Temperature correction accuracy up to 0.01 ° C, Temperature Fluctuation up to +/- 0.2 ℃~ +/- 0.05 ° C (depending on the specific model).
Principle
The equipment reduces the temperature of the medium in the Tank through the Compressor refrigeration system. The Control system monitors the temperature in real time through the High Accuracy Pt100 Sensor and precisely adjusts the refrigeration power using the P.I.D algorithm to achieve the set target temperature. The circulating pump drives the medium to flow within the system (domestic circulation) or between the system and the external container (external circulation) to ensure the uniformity and Stability of the temperature field.
Applications
This equipment is suitable for all kinds of laboratories, research institutions and production testing links that require High Accuracy thermostatic environment. Applications include but are not limited to: chemical synthesis, bioengineering, material testing, Petrochemicals, pharmaceutical research and development, Universities & colleges teaching experiments, etc.
Standards
The data did not mention specific national or industry standards that were met.
Steps
1. Inject an appropriate amount of suitable medium into the Tank.
2. Connect the power supply and turn on the power switch of the device.
3. Set the required target temperature and Miscellaneous parameters (e.g. alarm temperature) through the large LCD control panel.
4. Choose domestic circulation or external circulation mode as needed.
5. Start the device and start running.
6. After the operation, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
Notice
• Please ensure that the medium liquid level in the Tank is appropriate before use.
• Power supply voltage specified by the equipment and ensure good grounding.
• When the equipment is running, do not block the entry and exit trends to ensure normal heat dissipation.
• When making external circulation connections, make sure that the pipeline connections are firm and leak-free.
• When the equipment issues an over-temperature alarm, please check and troubleshoot in time.
• Regularly clean and maintain equipment to maintain optimum performance.
• Non-professionals should not disassemble or repair the equipment without authorization.