Overview
TENLIN SC-20A High Accuracy Thermostatic bath is a Temperature range from room temperature to 200 ℃ thermostatic equipment, Tank volume of 20L, using low noise Air-Cooled fully enclosed Compressor refrigeration, with self-developed Control system, designed to provide a stable, uniform temperature field, suitable for scientific research, testing and other areas of temperature control needs.
Features
1. Low Noise Air-Cooled Fully Enclosed Compressor Unit, Fast Cooling Speed and Strong Temperature Stability.
2. Control system adopts self-developed special software and temperature control technology, equipped with High Accuracy Pt100 Sensor and all imported electronic components.
3, with internal and external circulation system, external circulation can establish a second thermostatic field or as an external cold source, domestic circulation to ensure that the liquid temperature in the tank is highly uniform and stable.
4. With multiple protection systems, including cooling overheating/overcurrent protection, Control system over-temperature alarm (upper and lower limits can be set) and automatic load cutting function.
5. Equipped with high-end large LCD control instrument, easy to operate, support P.I.D automatic search or manual adjustment, strong temperature Stability.
6. With accurate temperature correction function (up to 0.01 ° C), Temperature Fluctuation up to +/- 0.01 ° C (depending on the model).
Principle
The Thermostatic bath is cooled by the built-in Compressor refrigeration system. The Control system P.I.D adjusts the temperature of the liquid in the tank according to the High Accuracy Pt100 Sensor, and controls the Power output of the heating or cooling unit to achieve fast, accurate temperature setting and stability. The circulation system (domestic circulation or external circulation) ensures that the temperature of the working medium is evenly distributed, thus providing a High Accuracy thermostatic environment.
Applications
Scientific research experiment, mass detection, bioengineering, chemical analysis, Measurement calibrating
Steps
1. Place the device in a smooth and ventilated place and connect it to the power supply.
2. Add an appropriate amount of heat transfer medium (such as silicone oil or water) to the Tank.
3. Turn on the power switch and set the required temperature and parameters (such as the upper and lower limits of the alarm temperature) through the large LCD control panel.
4. Choose domestic circulation or external circulation mode as needed.
5. Start the device and the system will run automatically, reaching the set temperature and maintaining stability.
6. After use, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
Notice
Equipment should be placed in a smooth, well-ventilated environment.
• Add an appropriate amount of heat transfer medium and ensure that its properties meet the Temperature range requirements.
• Please read the manual carefully before use to set the temperature and protection parameters correctly.
• During operation, do not block the entry and exit trends to ensure normal heat dissipation.
• The equipment has over-temperature alarm function, please check and troubleshoot in time when alarming.
• Before performing maintenance or cleaning, be sure to disconnect the power supply of the equipment.