Overview
The TENLIN SC-30 High Accuracy Thermostatic bath is a precision temperature control device with a Tank volume of 30L with a Temperature range from Room Temperature to 100 ° C. It uses an advanced Refrigeration and Control system designed to provide a stable, uniform thermostatic environment for laboratory and industrial applications.
Features
1. Low Noise Air-Cooled Fully Enclosed Compressor Unit, Fast Cooling Speed and Strong Temperature Stability.
2. Equipped with self-developed special software, high-standard Pt100 Sensor and imported electronic components, to achieve accurate temperature control.
3, with internal and external circulation system, external circulation can establish a second thermostatic field or as an external cold source, domestic circulation to ensure that the liquid temperature in the tank is highly uniform and stable.
4. It has a complete protection system, including cooling overheating and overcurrent protection, over-temperature sound and light alarm, and automatic load shutting function.
5. Adopting a large liquid crystal control instrument, it is easy to operate and supports P.I.D automatic search or manual adjustment.
6. Temperature correction accuracy up to 0.01 ° C, Temperature Fluctuation up to +/- 0.01 ° C (varies by model).
Principle
The Thermostatic bath works with the heating system through the built-in Compressor refrigeration system, and is monitored in real time with the High Accuracy Pt100 temperature sensor. The Control system uses the P.I.D algorithm to automatically adjust the cooling or Heating power according to the deviation between the set temperature and the measured temperature. The circulation pump drives the liquid in the tank for domestic circulation to ensure uniform temperature; when the external circulation is turned on, the thermostatic liquid can be drawn out to provide a stable temperature field or cold source for the external experimental vessel.
Applications
Laboratory thermostatic experiments, industrial process calibrating, material performance testing, thermostatic treatment of biochemical samples, temperature control of precision instruments
Steps
1. Place the device in a smooth and ventilated place and connect it to the power supply.
2. Inject an appropriate amount of heat transfer medium (such as silicone oil or water) into the Tank.
3. Turn on the power switch and set the required temperature and alarm parameters through the large LCD control panel.
4. Choose domestic circulation or external circulation mode as needed.
5. Start operation, and the equipment will automatically cool or heat to the set temperature and maintain stability.
6. After use, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
Notice
• Please ensure that the equipment is well grounded and use a power supply that meets the requirements.
• The injected heat transfer medium should be appropriate and should not exceed the maximum liquid level.
• When the equipment is running, do not block the entry and exit trends to ensure ventilated heat dissipation.
• When setting the over-temperature alarm temperature, the upper and lower limits should be set reasonably to ensure safety.
• When making external circulation connections, ensure that the pipeline connection is firm to prevent leakage.
• Regularly clean the surface and tank of the equipment to avoid dust or impurities affecting the performance.