Please contact customer service
Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, with internal and external circulation system can establish a second thermostatic field, using Air-Cooled Compressor cooling speed.
Category : Thermostatic Bath
Brand : TenLin
SKU : NB036131
Service :The delivery and service By NBCLab.Com
The TENLIN DC-2015C Program Temperature Control Low Temperature Circulating Bath is a temperature control device that uses a low-noise Air-Cooled fully enclosed Compressor unit for refrigeration, with fast cooling speed and high temperature Stability. Equipped with a High Accuracy Control system and an internal and external circulation system, the equipment can provide a precise, uniform and stable low temperature thermostatic environment, and can lead thermostatic liquids externally to establish a second thermostatic field or as a cold source.
1. Low Noise Air-Cooled Fully Enclosed Compressor Unit, Fast Cooling Speed and Strong Temperature Stability. 2. Control system adopts self-made temperature control technology developed by special software, equipped with High Accuracy Pt100 Sensor and imported electronic components. 3, with internal and external circulation system, external circulation can establish a second thermostatic field or as an external cold source, domestic circulation to ensure that the liquid temperature in the tank is uniform and stable. 4. Equipped with multiple protection systems, including cooling overheating/overcurrent protection, over-temperature sound and light alarm, and automatic load shutting function. 5. Equipped with a high-end large LCD control instrument, it is easy to operate and supports P.I.D automatic search or manual adjustment. 6, Temperature correction accuracy up to 0.1 ℃, Temperature Fluctuation up to +/- 0.1 ℃~ +/- 0.5 ℃ (depending on the model).
The device reduces the temperature of the liquid in the Tank through the Compressor refrigeration system. The Control system monitors the temperature in real time through the High Accuracy Pt100 Sensor according to the set target temperature, and uses the P.I.D algorithm to precisely adjust the refrigeration power for fast and stable temperature control. The circulation system (domestic circulation or external circulation) ensures uniform temperature of the working medium and delivers the thermostatic liquid to the desired location.
Laboratory thermostatic experiment, sample reaction thermostatic, material testing, biological fostering, chemical analysis, instrument matching chill down
The data did not mention specific compliance criteria.
1. Place the device in a smooth and ventilated place and connect it to the power supply. 2. Inject an appropriate amount of suitable medium (e.g. silicone oil, water, etc.) into the Tank. 3. Turn on the power switch and set the required target temperature and parameters (e.g. P.I.D value, alarm temperature, etc.) through the large LCD control panel. 4. Choose domestic circulation or external circulation mode as needed. 5. Start the device and it will run automatically until it reaches the set temperature and remains stable. 6. After use, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
• Please ensure that the equipment is placed in a smooth, well-ventilated environment for use. When adding media to the Tank, do not exceed the maximum volume and ensure that the appropriate media is used. • Do not block the liquid inlet and outlet when the equipment is running, and ensure that the circulation pipeline is smooth. • When setting the over-temperature alarm temperature, it should be set slightly higher than the Operating temperature to play an effective protective role. • The equipment has a protection function. In case of an alarm, please check and troubleshoot according to the prompts before using it. • Regularly clean the equipment surface and Tank, keep the equipment clean and drying. • Non-professionals should not disassemble or repair the equipment by themselves.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.