Overview
SHP-160 biochemistry cultivating box is a High Accuracy thermostatic equipment with cold and heat control functions, suitable for bacteria, mold, microbial fostering and breeding and testing. It adopts microcomputer intelligent control, is equipped with professional refrigeration technology, and the liner is made of stainless steel to ensure the stability and reliability of the equipment.
Features
1. Microcomputer intelligent control, with functions such as monitoring, temperature control, and protection.
2. Adopting professional refrigeration technology, the cooling effect is good, and the four corners of the inner tank of the box are designed in a semi-circular arc.
3. Equipped with dual display functions of set temperature and measured temperature for easy observation.
4. With low temperature compensation function, it can improve the temperature control accuracy during low temperature operation.
5. The box is equipped with lighting to facilitate the observation of the foster.
6. Using stainless steel liner, corrosion resistance.
Principle
The biochemistry cultivating box precisely adjusts the refrigeration and heating system through the microcomputer intelligent Control system to maintain a constant set temperature in the box. Its professional refrigeration technology ensures rapid cooling and stable temperature control, and the low temperature compensation function further optimizes the Temperature control accuracy in low temperature environments.
Applications
Bioengineering, medical research, environment protection, agriculture and forestry science, aquatic products, animal husbandry
Steps
1. Place the equipment in a stable and well-ventilated environment. Ambient Temperature is recommended to be 5~ 35 ° C.
2. Connect the 220V 50Hz power supply.
3. Set the required foster temperature (range 5~ 50 ℃) and timing time (range 1~ 9999 minutes) through the microcomputer control panel.
4. Place the object to be fostered on the bracket in the box and close the box door.
5. Start the device and the system will start working and display the measured temperature.
6. After the foster is over, take out the sample and turn off the power.
Notice
• Please ensure that the equipment is used at the specified Ambient Temperature (5~ 35 ℃).
• Power supply voltage must match 220V 50Hz.
• When the equipment is running, do not open and close the box door frequently, so as not to affect the temperature Stability.
• When cleaning the liner, wipe it with a soft cloth and avoid using corrosion cleaners.
• Regularly check the operating status of the equipment to ensure that the ventilating port is not blocked.