Overview
HONGKE CHP-80 Co2 Incubator is a precision instrument designed for fostering cells, tissues and bacteria. It is controlled by microcomputer module, with High Accuracy Temperature and CO2 concentration control, and is widely used in research and fostering work in microbiology, agricultural science, genetic engineering, immunology and other fields.
Features
1. Using microcomputer module control, digital display temperature and CO2 concentration, high control accuracy.
2. With CO2 concentration sound and light alarm device to ensure the safety of the experiment.
3. Equipped with CO2 and gas dual filtrating device.
4. Air sleeve Heating mode.
5. Equipped with a door heating device to prevent condensation and contamination of the Glass door, which is convenient for observing the situation in the box.
6. The four corners of the liner are semi-circular arc design, easy to clean.
Principle
The incubator precisely adjusts the temperature and carbon dioxide concentration in the chamber through a microcomputer Control system to create a stable simulated in vivo environment for cells or tissues to foster. The gas sleeve heating system ensures uniform and stable temperature. CO2 gas enters the chamber through the filtrating device, and the concentration is monitored by the Sensor. If it exceeds the set range, an alarm will be triggered.
Applications
Microbial research, agricultural scientific research, tissue fostering, cell fostering, bacterial fostering, genetic engineering, immunology research
Steps
1. Place the device in a position that meets the requirements of the working Ambient Temperature (+ 5~ 35 ° C), and connect the 220V 50Hz power supply.
2. Turn on the power switch and set the required temperature (room temperature + 5~ 60 ° C) and CO2 concentration (0~ 20%) through the microcomputer control panel.
3. Wait for the temperature and CO2 concentration in the box to reach and stabilize at the set value.
4. Put in the samples that need to be fostered.
5. Close the box door, the equipment enters the automatic operation state, and continuously monitors and adjusts the internal environment.
6. After the experiment, remove the sample and turn off the power.
Notice
• Power supply voltage is 220V 50Hz before use.
Equipment should work at Ambient Temperature + 5~ 35 ℃.
• Pay attention to the CO2 alarm prompt, when the concentration deviation exceeds the set value +/- 1%, the sound and light alarm will be triggered.
• Clean the liner regularly to maintain hygiene.
• Do not open the box door for a long time while the equipment is running, so as not to affect the internal environment Stability.
Please pay attention to safety during operation.