Modular design and intelligent Sensor technology, with automatic temperature compensation and full software Adjustment. Range 0-10000ppm, accuracy ≤ 3% F.S, Response Time ≤ 30 seconds, Explosion-proof level ExdIICT6, support a variety of Sampling methods.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB036997
Service :The delivery and service By NBCLab.Com
SK/MIC-600-SO2-Y/10000 online sulfur dioxide detector is a fixed installation gas concentration monitor of SKYEAGLEE brand with Modular design, intelligent Sensor detection technology and overall flameproof (d) structure. Standard configuration with dot matrix LCD liquid crystal display, support three-wire system 4~ 20mA analog and RS485 digital signal output, optional programmable switch output and other modules, support Output signal fine-tuning, convenient system networking and maintenance.
1. Modular design and intelligent Sensor detection technology. 2. Integral flameproof (d) structure, fixed Installation method. 3. Automatic temperature compensation, zero point, full scale drift compensation. 4. Impacts against high concentration gases with automatic protection function. 5. Full software Adjustment, users can calibrate themselves through 3 buttons, easy to operate. 6. Standard configuration with dot matrix LCD liquid crystal display, support three-wire system 4~ 20mA analog and RS485 digital signal output. 7. Optional programmable switch output and other modules, support Output signal fine-tuning, convenient system networking and maintenance.
The detector adopts the Sensor of electrochemistry principle to continuously monitor the concentration of sulfur dioxide (SO2) in the environment through Sampling methods such as diffusion type, pipeline type, flow type or pump type. The Sensor converts the gas concentration signal into an electrical signal, which is processed by the internal processing circuit, and is output through 4-20mA current signal or RS485 digital signal.
Paints room, incinerator, scientific research, production workshop, company, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, petroleum and petrochemical, chemical plant, smelter, steel plant, coal plant, thermal power plant, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, safety protection equipment monitoring in dangerous places, etc.
Explosion-proof marking: ExdIICT6
1. Installation: Select the diffusion, pipeline, circulation or pump-suction Installation method according to the site conditions, and connect the cable as required (Shielding cable is recommended). 2. Wiring: Connect the power supply (DC12~ 30V) and signal output line (4-20mA/RS485) according to the electrical wiring definition diagram. 3. Power on: Power on, the instrument starts and performs self-test. 4. Calibrate: If you need to calibrate, you can enter the calibrate mode through the 3 buttons on the instrument, and follow the prompts to calibrate the zero point and range. 5. Settings: Set parameters such as alarm points through buttons. 6. Operation: The instrument enters the continuous monitoring state, displays the concentration in real time and Outputs signal.
• Please select according to the actual working conditions, the information is for reference only. • Operating ambient temperature range is -20 ℃~ + 50 ℃, Humidity range is 10% RH~ 90% RH (no condensation). • The working absolute pressure is in the range of 106KPa +/- 20KPa. • It is recommended to use Shielding cable for connecting cables, with a single wire diameter of not less than 1.5mm and a connection distance of not more than 1000 meters. • Sensors have a lifespan of approximately 2 years and require regular maintenance and calibrating. • The instrument is explosion-proof type, and the explosion-proof mark is ExdIICT6. The installation and use must comply with the relevant specifications of explosion-proof places. • Protection Rating is IP66, but the installation still needs to be careful to avoid long-term exposure to extreme harsh environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.