Overview
SKYEAGLEE SK/MIC-600-SO2-Y/40000 In-line sulfur dioxide detector is a fixed installation gas concentration monitor with Modular design, intelligent Sensor detection technology and overall flameproof (d) structure. Standard configuration with dot matrix LCD LCD display, support three-wire system 4~ 20mA analog and RS485 digital signal output, optional programmable switch output and other modules, support Output signal fine-tuning, easy system networking and maintenance.
Features
1. Modular design is adopted to support customized products.
2. Sensor detection technology.
3. Integral flameproof (d) structure, explosion-proof marking ExdIICT6.
4. Automatic temperature compensation, zero point and full scale drift compensation.
5. Impacts against high concentration gases with automatic protection function.
6. Full software Adjustment, users can calibrate themselves through 3 buttons, easy to operate.
7. Support a variety of signal output (such as 4-20mA, RS485, programmable switching).
8. Protection Rating IP66, adapt to harsh environment.
Principle
The detector adopts electrochemistry principle Sensor, and continuously detects the concentration of sulfur dioxide gas in the environment through diffusion, pipeline, flow or pump-suction Sampling methods. The detected concentration signal is processed and converted into a standard current signal (4-20mA) or a digital signal output, which can be displayed in real time through the point matrix LCD LCD screen.
Applications
Paints room, incinerator, scientific research, production workshop, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, petroleum and petrochemical, chemical plant, smelter, steel plant, coal plant, thermal power plant, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, safety protection equipment monitoring in dangerous places
Standards
Explosion-proof mark ExdIICT6
Steps
1. Connect the power supply and signal lines correctly according to the electrical wiring definition diagram.
2. After power on, the instrument enters the working state, and the LCD screen displays real-time concentration.
3. Enter the menu through the three buttons on the instrument, and perform operations such as alarm point setting and signal output fine-tuning.
4. When calibrating is required, enter the calibrate mode through the button, and use the standard gas to calibrate the zero point and range according to the prompts.
Notice
* Please select the model according to the actual working conditions, the information is for reference only.
* Working ambient temperature range is -20 ℃~ + 50 ℃, Humidity range is 10% RH~ 90% RH (no condensation).
The working pressure is 106KPa +/- 20KPa.
* It is recommended to choose a single three-core Shielding cable with a diameter of ≥ 1.5mm for the connection cable.
The maximum connection distance is ≤ 1000 meters.
* Sensor life is approximately 2 years.
The instrument is explosion-proof equipment, and installation and maintenance must comply with relevant explosion-proof safety regulations.