Please contact customer service
Using flameproof structure, suitable for dangerous places. With automatic temperature compensation and zero drift compensation function, Response Time ≤ 30 seconds, detection accuracy ≤ 3% F.S. Support 4-20mA and RS485 output, convenient System integration.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037000
Service :The delivery and service By NBCLab.Com
SK/MIC-600-NO2-Y/1 online nitrogen dioxide detector is a fixed installation gas concentration monitoring equipment of SKYEAGLEE brand. The product adopts Modular design, intelligent Sensor detection technology and overall explosion-proof (d) structure, standard configuration with dot matrix LCD liquid crystal display, supports three-wire system 4~ 20mA analog and RS485 digital signal output, and can customize programmable switch output and other modules according to user request, which is convenient for system networking and maintenance.
1. Modular design, Intelligent Sensor detection technology and integral flameproof (d) structure. 2. With automatic temperature compensation, zero point and full scale drift compensation function. 3. Impact protection against high concentration gases. 4. Support full software calibrate, users can calibrate by themselves through 3 buttons, easy to operate. 5. Provide two-wire 4-20mA output (three-wire system is also mentioned in the data, subject to the data). 6. Output signal fine-tuning is supported, which is convenient for system networking and maintenance.
The detector adopts the Sensor of atmospheric monitoring principle, and continuously monitors nitrogen dioxide (NO2) gas in the environment through optional Sampling methods such as diffusion type, pipeline type, flow type or pump type. The Sensor converts the gas concentration signal into an electrical signal, and after processing by the internal processing circuit, it uses 4-20mA current signal and RS485 digital signal output, and can display the concentration value in real time through the LCD display screen.
Paints room, incinerator, scientific research, production workshop, company, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, petroleum and petrochemical, chemical plant, smelter, steel plant, coal plant, thermal power plant, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, safety protection equipment monitoring in dangerous places, etc.
Explosion-proof marking: ExdIICT6
1. Installation: Select the diffusion, pipeline, circulation or pump-suction Installation method according to the site conditions, and connect the cable as required (Shielding cable is recommended). 2. Wiring: Connect the power supply (DC12~ 30V) and Output signal line (4-20mA, RS485, etc.) according to the electrical wiring definition diagram. 3. Power on: Power on, the device starts and performs self-test. 4. Calibrate: If you need to calibrate, you can enter the calibrate mode through the 3 buttons on the device, and follow the prompts to calibrate the zero point and range. 5. Settings: Set parameters such as alarm points through buttons or communication. 6. Operation: The equipment enters the continuous monitoring state, displays and outputs the gas concentration signal in real time.
* Please select the model according to the actual working conditions, the information is for reference only. * Working ambient temperature range is -20 ℃~ + 50 ℃, Humidity is 10% RH~ 90% RH (no condensation). The working pressure is 106KPa +/- 20KPa. * It is recommended to choose a single wire diameter ≥ 1.5mm three-core Shielding cable for the connection cable, and the connection distance should be ≤ 1000m. * Sensors have a lifespan of approximately 2 years and require regular maintenance and calibrating. * Equipment Protection Rating is IP66, but the installation still needs to be careful to avoid long-term exposure to extreme harsh environment. * Alarm point can be set as needed, output 2 passive node signal.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.