Please contact customer service
Using flameproof structure, suitable for flammable environment. With automatic temperature compensation and full software Adjustment, accuracy ≤ 3% F.S, Response Time ≤ 30 seconds, support 4-20mA and RS485 signal output, Modular design is easy to maintain.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037003
Service :The delivery and service By NBCLab.Com
SK/MIC-600 On-line nitric oxide detector is an on-line gas concentration detector with Modular design, intelligent Sensor detection technology, integral flameproof (d) structure, and fixed Installation method. The standard configuration is LCD with dot matrix, 3-wire 4~ 20mA analog and RS485 digital signal output, optional configuration for programmable switch output and other modules, support Output signal fine-tuning, convenient system networking and maintenance.
1. Modular design is adopted to support customized configuration. 2. Sensor detection technology. 3. Integral flameproof (d) structure, suitable for use in hazardous locations. 4. Automatic temperature compensation, zero point and full scale drift compensation. 5. Impacts against high concentration gases with automatic protection function. 6. Full software Adjustment, users can calibrate themselves through 3 buttons, easy to operate. 7. Standard configuration provides three-wire 4~ 20mA analog and RS485 digital signal output. 8. Optional programmable switch output module.
Sampling methods such as diffusion, pipeline, flow or pump suction are used to continuously monitor the concentration of nitric oxide (NO) in the environment. The sensor converts the gas concentration signal into an electrical signal, and outputs a standard 4-20mA current signal or RS485 digital signal after processing by the internal processing circuit, and can display the concentration value through the point array LCD screen.
Paints room, incinerator, scientific research, production workshop, company, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, petroleum and petrochemical, chemical plant, smelter, steel plant, coal plant, thermal power plant, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, safety protection equipment monitoring in dangerous places, etc.
Explosion-proof marking: ExdIICT6
1. According to the installation requirements, choose the diffusion type, pipeline type, circulation type or pump type Sampling method to install the detector. 2. Connect the power supply (DC12~ 30V) and signal output line (three-core cable, single wire diameter ≥ 1.5mm) according to the electrical wiring definition diagram. 3. After power on, the instrument enters the working state, and the point array LCD LCD screen displays the current gas concentration. 4. Users can enter the menu through the 3 buttons on the instrument to perform operations such as zero-point calibrating, full-scale calibrating and alarm point setting. 5. After the calibrating or setting is completed, the instrument will continuously monitor and Output signal according to the set parameters.
* When installing, ensure that the working Ambient Temperature is -20 ℃~ + 50 ℃, Humidity ≤ 90% RH (no condensation), and the absolute pressure is within the range of 106KPa +/- 20KPa. It is recommended to use a Shielding cable for the connection cable, and the connection distance should not exceed 1000 meters. * Sensors have a lifespan of approximately 2 years and require regular maintenance and calibrating to ensure detection accuracy. The instrument is designed to be flameproof, and installation and maintenance must comply with the relevant operating procedures for explosion-proof electrical equipment. * The alarm point is a parameter that can be set, and the user should set it reasonably according to the actual safety needs. * Please select according to the actual working conditions (such as gas type, range, environmental conditions, etc.), this information is for reference only.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.