Electrochemical sensor, range 0-4000ppm, resolution 0.1ppm, detection accuracy ≤ 3% F.S. With automatic temperature compensation, full software Adjustment, Response Time ≤ 30 seconds, support 4-20mA and RS485 signal output, overall flameproof structure, Protection Rating IP66.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037012
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-600-PH3-Y/4000 On-line phosphating hydrogen detector is a fixed installation gas monitor with Modular design, intelligent Sensor detection technology and overall flameproof (d) structure. Standard configuration with dot matrix LCD liquid crystal display, support three-wire system 4~ 20mA analog and RS485 digital signal output, optional programmable switch output and other modules, support Output signal fine-tuning, convenient system networking and maintenance.
1. Modular design and intelligent Sensor detection technology. 2. Integral flameproof (d) structure, fixed Installation method. 3. Standard configuration with dot matrix LCD liquid crystal display. 4. Support 3-wire 4~ 20mA analog and RS485 digital signal output. 5. Optional programmable switch output and other modules, support customization. 6. Output signal fine-tuning function is supported, which is convenient for system networking and maintenance. 7. With automatic temperature compensation, zero point and full scale drift compensation function. 8. Impact protection against high concentration gases. 9. Full software Adjustment, users can calibrate themselves through 3 buttons, easy to operate.
The detector adopts the Sensor of electrochemistry principle, and continuously detects the phosphating hydrogen (PH3) gas concentration in the environment through the Sampling method of diffusion type, pipeline type, flow type or pump type, and converts the concentration signal into 4-20mA current signal or RS485 digital signal output.
Paints room, incinerator, scientific research, production workshop, company, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, petroleum and petrochemical, chemical plant, smelter, steel plant, coal plant, thermal power plant, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, safety protection equipment monitoring in dangerous places, etc.
Explosion-proof mark: ExdIICT6, Protection Rating: IP66
1. Installation: Select the diffusion type, pipeline type, circulation type or pump suction Installation method according to the on-site working conditions to ensure that the working environment meets the requirements (temperature -20~ 50 ℃, Humidity ≤ 90% RH without condensation). 2. Wiring: Connect the power supply (DC12~ 30V) and signal output cable (three-core cable, single wire diameter ≥ 1.5mm, Shielding cable is recommended, the connection distance is ≤ 1000m) according to the electrical wiring definition diagram. 3. Power on debugging: After power on, confirm the normal operation of the device through the point matrix LCD liquid crystal display. 4. Calibrate: Use 3 buttons to enter the calibrate mode to perform software calibrate of zero and range. 5. Alarm setting: Set the alarm point of two passive node signals through the device or system. 6. System networking: 4-20mA or RS485 signal is connected to PLC, DCS or computer Control system, and can be fine-tuned Output signal.
* Please select the model according to the actual working conditions, the information is for reference only. * Ensure that the working environment is at a temperature of -20 ℃~ + 50 ℃, Humidity 10% RH~ 90% RH without condensation, absolute pressure in the range of 106KPa +/- 20KPa. * It is recommended to use Shielding cable for connecting cables, with a single wire diameter of not less than 1.5mm. * Sensors have a lifespan of approximately 2 years and require regular maintenance and calibrating. The equipment is flameproof, and the installation and maintenance must comply with the relevant safety regulations for explosion-proof electrical equipment. * Impact of high concentration gases is avoided, the equipment has automatic protection function, but still need to pay attention to the Operating Environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.