Please contact customer service
Using infrared NDIR Sensor, detection accuracy ≤ +/- 3% F. S, Response Time ≤ 10 seconds. With pump-suction three-speed sampling, 200,000 data storage, temperature and pressure compensation functions, Explosion-proof level up to Exia ⅱ CT4.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037063
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-CH4-Y/100% NDIR Portable Methane Detector is a Handheld Gas detection device using pump-suction sampling and infrared NDIR Sensor principle. The instrument is based on EFM ultra-low power 32-bit ARM processor, combined with High Accuracy imported Sensor and stable circuit design, to achieve rapid, accurate and stable detection of methane gas, and is equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation.
1. Imported High Accuracy Infrared NDIR Sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Accurate and Stable Measurement. 3. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, and print data can be downloaded. 6. Built-in long-life imported micro sampling pump, with low, medium and high adjustable three gears, and with automatic cleaning function of gas circuit. 7. Meet the explosion-proof qualification certification, Explosion-proof level is Exia II CT4, the shell adopts anti-skid, waterproof, dustproof and explosion-proof two-color mold design. 8. With self-calibration, zero-point calibration, multi-point calibration functions, support temperature and pressure compensation. 9. With a key to restore factory settings, gas concentration unit fast switching, self-programming alarm parameters, STEL and TWA functions. 10. Provide the usual detection and patrol two detection modes, automatically prompt instrument failure, Sensor calibration expiration and failure.
The Portable methane detector uses the pump-suction Sampling method, and the environment gas is sucked into the detection chamber through the built-in micro-sampling pump. The methane component in the gas has absorption characteristics for specific wavelengths of infrared light. The NDIR (non-dispersion infrared) Sensor inside the instrument calculates the concentration value of methane gas by measuring the change of infrared light Absorption intensity. The measurement results are processed by the High Accuracy amplifier and processor and displayed in real time on the screen.
Environment monitoring, confined space operation safety inspection, industrial safety inspection, gas leakage investigation, emergency rescue
ExiaⅡCT4
1. Turn on and warm up for about 30 seconds. 2. Select the detection mode (usually detection mode or patrol mode) as needed. 3. Set alarm parameters, STEL/TWA values, etc. through the menu (if necessary). 4. Place the sampling tube in the area to be tested, and the instrument inhales the gas through the built-in pump for detection. 5. Read methane concentration value, MAX Maximum, STEL, TWA and other information in real time through the screen. 6. After the test is completed, you can use the USB interface to connect to the computer to download the stored data. 7. Regularly use the automatic cleaning function to clean the air circuit, or perform zero and multi-point calibration.
* Please use within the valid period of instrument calibration and calibrate regularly. * Avoid use in extreme environments (beyond -30~ 50 ℃ Operating temperature, 10~ 95% RH non-condensing Humidity range). * Note that the Operating Pressure should be kept within the range of 86~ 106kPa. The instrument has an explosion-proof design, but it still needs to be operated in strict accordance with the specifications for the use of explosion-proof electrical equipment in hazardous areas. Avoid strong impact or immersion of the instrument in liquids. * When the instrument indicates that the Sensor is faulty, the calibration expires or fails, it should be dealt with in time. When not in use for a long time, please store it properly according to the storage temperature (-30~ 70 ° C).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.