Imported Electrochemical sensor, range 0-20000ppm, resolution 0.1ppm, accuracy ≤ +/- 3% F.S. With pump-suction three-speed sampling, 200,000 data storage, self-calibration and temperature and pressure compensation functions, Response Time ≤ 10 seconds, Explosion-proof level Exia ⅱ CT4.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037067
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-CO-Y/20000 Portable Carbon Monoxide Detector is a Handheld Gas detection device. The instrument uses imported Electrochemical sensors, combined with High Accuracy low temperature drift amplifiers and stable power processing circuits to ensure fast detection, accurate measurement, stability and Repeatability. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, built-in micro sampling pump, adopts pump suction detection method, suitable for gas concentration monitoring and alarm in various environments.
1. High Accuracy Electrochemical sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Accurate and Stable Measurement. 3.3.5-Inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. Large-capacity Data storage function, which can store about 300,000 sets of data, and the storage interval is adjustable. 5. Equipped with USB interface, supports high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high three-speed adjustment, with automatic cleaning gas circuit function. 7. Through explosion-proof certification, Explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration function, with temperature and pressure compensation. 10. Support one key to restore factory settings, gas concentration unit can be switched, with self-programming alarm parameters, STEL and TWA functions. 11. Provide two detection modes, usually detection and patrol, to automatically prompt instrument failure and Sensor status.
The detector works based on the principle of Electrochemical sensor. The Sensor detects carbon monoxide gas in the environment and generates an electrical signal proportional to the gas concentration. The signal is amplified by the built-in High Accuracy and Low Temperature Drift Amplifier, and then the signal stability is ensured by the stable power supply circuit. Finally, the 32-bit ARM processor performs arithmetic analysis, and the results are displayed on the screen in real time, and an alarm is triggered when the concentration exceeds the standard. The built-in micro-sampling pump actively sucks the gas to be tested into the detection gas path for analysis.
Industrial safety, environment monitoring, confined space operation, emergency rescue, municipal pipe network maintenance
ExiaⅡCT4
1. Turn on and warm up for about 30 seconds. 2. Select detection mode (usually detection mode or patrol mode) through the graphical menu. 3. Adjust the sampling pump gear (low, medium and high) as needed. 4. Extend the sampling tube into the area to be measured, and the instrument starts to detect and display the concentration value in real time. 5. You can perform zero-point calibration, multi-point calibration or view historical data through the menu. 6. Use the USB port to connect to the computer and download or print the stored data. 7. After use, you can use the pump's cleaning function to clean the air circuit and then shut down.
• Please use within the valid period of instrument calibration and calibrate regularly. • Avoid long-term operation in extreme temperatures (below -30 ° C or above 50 ° C) or high Humidity condensing environments. • Pay attention to the Operating Pressure Range of the instrument (86~ 106kpa) and avoid using it in an environment with abnormal air pressure. • Although the instrument is waterproof and dustproof, it should still be avoided from long-term immersion or exposure to a large amount of dust. • When using in explosion-proof areas, it is necessary to strictly abide by relevant safety regulations and do not disassemble the instrument in dangerous places. Sensors have a lifespan of about 3 years and need to be replaced when they expire or fail. • Before performing operations such as calibration or factory reset, please confirm that the environment is safe and understand the meaning of the operation. When charging or transferring data, make sure to do so in a safe area.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.