Adopt pump suction sampling, equipped with imported High Accuracy Electrochemical sensor, Response Time ≤ 10 seconds, range 0-7000ppm. With 3.5 inch full color screen, Data storage, self-calibration and temperature and pressure compensation functions, Explosion-proof level Exia ⅱ CT4.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037078
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-H2S-Y/7000 Portable hydrogen sulfide detector is a Handheld Gas detection device designed for rapid and accurate detection of hydrogen sulfide (H2S) gas concentration in the environment. The instrument uses imported Electrochemical sensors and advanced circuit processing technology, combined with pump-suction Sampling method, to ensure fast, stable measurement, Repeatability is good, and is equipped with a large-size full-color display, supports Chinese and English graphic menu operation, user-friendly.
1. Imported High Accuracy Electrochemical sensor to ensure detection accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Long-term Stability. 3. Equipped with a 3.5-inch TFT full-color display, it supports Chinese and English graphical menus and real-time detection of trend analysis charts. 4. With large-capacity Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Built-in long-life imported micro sampling pump, support low, medium and high three-speed adjustment, with automatic cleaning gas circuit function. 6. In line with explosion-proof certification, Explosion-proof level is Exia II CT4, and the shell is designed with a two-color mold that is non-slip, waterproof, dustproof and explosion-proof. 7. Support USB interface for high-speed data transmission, allowing you to download and print data. 8. With self-calibration, zero-point calibration, multi-point calibration, temperature and pressure compensation functions. 9. Provide one key to restore factory settings, quick switching of gas concentration units, self-programming to set alarm parameters and STEL/TWA functions. 10. Support two detection modes of normal detection and patrol, and have the function of automatic prompt of fault, Sensor expiration and failure.
The detector works based on the principle of electrochemistry sensing. The built-in micro-sampling pump sucks the environment gas into the instrument, and the gas reacts electrochemically with the electrolysis solution in the Sensor to generate an electrical signal proportional to the hydrogen sulfide concentration. After the signal is amplified by a High Accuracy, Low Temperature Drift amplifier and a stable power supply circuit, it is analyzed and calculated by a 32-bit ARM processor. Finally, the real-time gas concentration value is displayed on the screen, and an alarm is triggered when the concentration exceeds the standard.
Petrochemicals, natural gas extraction and transportation, sewage treatment, metallurgical smelting, municipal pipe gallery, confined space operation, environment monitoring, emergency rescue, industrial safety inspection
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select "normal detection mode" or "patrol mode" through the menu. 3. Set the sampling pump gear: According to the detection environment, set the sampling pump to low, medium or high in the menu. 4. Start detection: The sampling tube is inserted into the area to be measured, and the instrument automatically samples and displays the H2S concentration in real time. 5. Data viewing and export: View historical data, STEL/TWA values through the menu, or export data by connecting to a computer through the USB interface. 6. Calibration and settings: Regularly perform zero or multi-point calibration through the menu, and can set parameters such as Alarm threshold and unit. 7. Shutdown: After the detection is completed, press the power button for a long time to shut down.
* Please read the instructions before use to ensure that it is used under the instrument range (0-7000ppm) and specified environmental conditions (temperature -30~ 50 ℃, Humidity 10~ 95% RH without condensation). * Avoid use in environments with strong electromagnetic interference, high corrosion gases, or substances that may damage the Sensor. * Periodic Sensor calibration to ensure measurement accuracy, the instrument will prompt calibration expired or Sensor failure. Instruments are explosion-proof, but must not be disassembled or charged in hazardous locations beyond the Explosion-proof level. * The sampling tube should be kept clean and unblocked to avoid blockage affecting the sampling. After use, the cleaning function that comes with the instrument can be used to clean the air passage. * The instrument has a built-in rechargeable battery, please use the matching charger to charge in a safe place. If the instrument alarms, evacuate to a safe area immediately and identify the cause. * Please store in a drying and cool place (-30~ 70 ℃) to avoid direct sunlight and mechanical Impact.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.