Please contact customer service
Adopt pump-suction third-gear sampling, equipped with imported Electrochemical sensor, Response Time ≤ 10 seconds, accuracy ≤ +/- 3% F.S. With 3.5-inch full-color screen, 200,000 data storage, USB transmission and self-cleaning functions, support temperature and pressure compensation.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037085
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-SO2-Y/20 is a Portable sulfur dioxide detector belonging to the SK/MIC-800 series. The instrument adopts imported High Accuracy Electrochemical sensor, combined with 32-bit ARM processor and professional circuit design to ensure fast detection, accurate measurement, stable and good Repeatability. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, and has a built-in micro sampling pump, suitable for pump suction detection.
1. Imported High Accuracy Electrochemical sensor to ensure detection accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Measurement Stability. 3. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, allowing you to download and print data. 6. Built-in long-life imported micro sampling pump, providing low, medium and high adjustable cleaning air circuit functions. 7. In line with explosion-proof certification, Explosion-proof level is Exia II CT4, and the shell is designed with a two-color mold that is non-slip, waterproof, dustproof and explosion-proof. 8. With self-calibration, zero-point calibration, multi-point calibration functions, and with temperature and pressure compensation. 9. Support one-click factory reset, gas concentration units can be quickly switched between LEL and% LEL. 10. With self-programming function, alarm parameters, STEL and TWA functions can be set, and two modes of detection and patrol are provided.
The detector uses a pump-suction Sampling method, and the environment gas is sucked into the detection gas circuit through a built-in micro-sampling pump. The gas contacts the imported Electrochemical sensor inside the instrument, and the Sensor generates an electrical signal proportional to the concentration of sulfur dioxide. The signal is amplified and processed by a High Accuracy, Low Temperature Drift amplifier and a stable power processing circuit, and finally calculated and displayed by a 32-bit ARM processor. The instrument has the function of automatic cleaning of the gas circuit and trouble warning.
Environment Monitoring, Confined Space Operation Safety Inspection, Industrial Process Control, Emergency Response and Accident Investigation, Occupational Health and Safety Protection
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select "normal detection mode" or "patrol mode" through the menu. 3. Set the sampling pump gear: Select the low, medium or high Sampling flow rate as needed. 4. Detection: The sampling tube is placed in the area to be tested, and the instrument automatically samples and displays the real-time concentration. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration and settings: Enter the menu as needed to perform zero-point calibration, multi-point calibration or alarm parameter setting. 7. Shutdown: After the detection is completed, press the power button for a long time to shut down.
• Please read the manual before use to ensure that it operates in the working environment specified by the instrument (temperature -30~ 50 ° C, Humidity 10~ 95% RH without condensation). • Avoid disassembling or repairing instruments in hazardous locations that exceed the Explosion-proof level. • Regularly calibrate the Sensor to ensure detection accuracy, and the instrument will prompt when the Sensor calibration expires or fails. • When sampling, please ensure that the sampling tube is unobstructed to avoid blockage affecting the test results. • The instrument has a built-in rechargeable battery, please use the matching charger to charge to avoid overcharging or short circuit. • Keep the instrument clean and avoid contact with corrosion substances. Although the shell is anti-corrosion, it still needs to be properly kept. • If the instrument malfunctions, please do not continue to use it, and contact a professional for maintenance. • When storing, place in a drying, temperature appropriate (-30~ 70 ℃) environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
