Please contact customer service
Imported Electrochemical sensor, range 0-1000ppm, resolution 0.1ppm, Response Time ≤ 10 seconds. With pump-suction three-speed sampling, 200,000 data storage, temperature and pressure compensation and self-cleaning function, Explosion-proof level Exia ⅱ CT4.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037089
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-NO-Y/1000 Portable Nitric Oxide Detector is a Handheld Gas detection device that uses the pump-suction Sampling method to detect nitric oxide (NO) gas concentration in the environment or confined space. The instrument uses EFM ultra-low power 32-bit ARM processor, equipped with imported High Accuracy Electrochemical sensor, combined with High Accuracy low temperature drift amplifier and stable power processing circuit to ensure fast, accurate and stable detection. The instrument is equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphic menu operation, and has various functions such as Data storage and USB data transmission.
1. Imported High Accuracy Electrochemical sensor for fast, accurate and stable detection. 2. Using High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit, Repeatability is Good. 3. Equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphical menu operation, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Provide USB interface for high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high gear adjustment to clean the gas path. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration function, with temperature and pressure compensation. 10. Support one-click factory reset, gas concentration units can be quickly switched between LEL and% LEL. 11. With self-programming function, alarm parameters, STEL and TWA function parameters can be set. 12. Provide two detection modes of normal detection and patrol, and the gas circuit has automatic cleaning function.
The detector adopts the pump-suction Sampling method, which actively sucks the environment gas into the gas path through the built-in micro-sampling pump. The gas contacts the imported Electrochemical sensor inside the instrument, and the Sensor converts the concentration signal of nitric oxide gas into an electrical signal. The electrical signal is amplified and conditioned by a High Accuracy low temperature drift amplifier and a stable power processing circuit, and then the EFM ultra-low power 32-bit ARM processor performs data processing and analysis. Finally, the real-time gas concentration value is displayed on the screen, and an alarm is triggered when the concentration exceeds the standard.
Environment Monitoring, Confined Space Operation Safety Testing, Industrial Safety, Emergency Response, Occupational Health Protection
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select "normal detection mode" or "patrol mode" through the menu. 3. Set the sampling pump gear: select the low, medium or high position for sampling as needed. 4. Start detection: The sampling tube is inserted into the test area, and the instrument displays the gas concentration in real time. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration and setting: Regularly carry out zero-point calibration or multi-point calibration through the menu, and can set alarm parameters according to needs. 7. Shutdown: After the detection is completed, press the power button for a long time to shut down.
* Do not use under conditions exceeding the Operating Ambient Temperature (-30~ 50 ° C) and Humidity (10~ 95% RH without condensation). * Avoid strong impact or drop of the instrument to prevent damage to internal Sensors and circuits. * Regularly calibrate the instrument to ensure detection accuracy, and the instrument will prompt when the Sensor calibration expires or fails. * When used in potentially explosive environments, it is necessary to ensure that the Explosion-proof level of the instrument (Exia II CT4) meets the field requirements. * After use, it is recommended to run the sampling pump through the high-end position to clean the gas path to avoid residual gas affecting the next measurement. * The instrument has a built-in lithium battery, please use the matching charger when charging, and avoid charging in a high temperature environment. If the instrument malfunctions, please do not disassemble it yourself. You should contact a professional for repair. * When storing, please place in a drying and cool place to avoid long-term exposure to extreme temperatures (storage temperature: -30~ 70 ° C).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.