Imported Electrochemical sensor, detection accuracy ≤ 3% F.S, Response Time ≤ 10 seconds. With pump-suction three-speed sampling, 200,000 data storage, TFT color screen display and temperature and pressure compensation functions, Explosion-proof level Exia ⅱ CT4.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037092
Service :The delivery and service By NBCLab.Com
SK/MIC-800-NH3-Y/200 Portable Ammonia Gas Detector is a Handheld Gas detection device launched by SKYEAGLEE. The instrument adopts imported High Accuracy Electrochemical sensor, combined with professional circuit design, can quickly, accurately and stably detect the concentration of ammonia in the environment, and has an alarm function. The instrument is equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphic menu operation, and has a built-in micro sampling pump, which is suitable for Gas detection in various environments.
1. Imported High Accuracy Electrochemical sensor for fast, accurate and stable detection. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Measurement Reliability. 3. Equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Provide USB interface for high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high three-speed Flow rate adjustment, with automatic cleaning gas circuit function. 7. Passed the explosion-proof qualification certification, the explosion-proof level is Exia II CT4, and the shell is designed with a two-color mold that is non-slip, waterproof, dustproof and explosion-proof. 8. With self-calibration, zero-point calibration, multi-point calibration functions, and with temperature and pressure compensation. 9. Support one key to restore factory settings, gas concentration unit can be switched, with self-programming alarm parameters, STEL and TWA functions. 10. Provide the usual detection and patrol two detection modes, automatically prompt instrument failure, Sensor calibration expiration and failure.
The detector uses a pump-suction Sampling method, and the environment gas is sucked into the instrument through a built-in micro-sampling pump. The gas is in contact with the built-in imported Electrochemical sensor, and the Sensor generates an electrical signal proportional to the ammonia concentration. After the signal is amplified by a High Accuracy, Low Temperature Drift amplifier and a stable power processing circuit, it is analyzed and calculated by a 32-bit ARM processor. Finally, the ammonia concentration value is displayed on the screen in real time, and an alarm is triggered when the concentration exceeds the standard.
Environment monitoring, confined space operation safety inspection, industrial process control, emergency accident handling, occupational health and safety
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select "normal detection mode" or "patrol mode" through the menu. 3. Set the sampling pump gear: adjust the sampling pump to low, medium or high grade as needed. 4. Detection: The sampling tube is inserted into the area to be measured, and the instrument automatically samples and displays the real-time concentration. 5. View data: You can view real-time values, MAX Maximum, STEL, TWA and other data through the screen, or export historical data through the USB interface. 6. Calibration and setting: zero-point calibration, multi-point calibration or setting alarm parameters through self-programming function as needed. 7. Shutdown: After the detection is completed, press the power button to shut down.
• Before use, please ensure that the instrument is fully charged and used within the range of Ambient Temperature (-30~ 50 ° C) and Humidity (10~ 95% RH without condensation) specified in the manual. • Avoid long-term use in environments containing silicon, lead, sulfur, phosphorus, etc., to prevent Sensor poisoning or performance degradation. • The instrument is designed to be explosion-proof, but the battery must not be removed or replaced in hazardous locations beyond the explosion-proof level. • Regularly calibrate the instrument to ensure detection accuracy, and the calibrating cycle is recommended to be no more than 6 months. • When sampling, ensure that the sampling pipeline is clear and free of blockage or severe bending. • The built-in Sensor of the instrument has a lifespan of about 3 years and needs to be replaced in time when it expires or expires. • When cleaning the instrument, please use a soft damp cloth to wipe the shell, do not use corrosion chemical solvents or direct soaking. • When not in use for a long time, please turn off the instrument and store it in a drying and cool (-30~ 70 ° C) environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.