Please contact customer service
Imported Electrochemical sensor, Response Time ≤ 10 seconds, accuracy ≤ +/- 3% F.S. With pump suction sampling, 3.5 inch color screen display, 200,000 data storage and explosion-proof design, suitable for a variety of environment detection.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037102
Service :The delivery and service By NBCLab.Com
SK/MIC-800-PH3-Y/4000 is a Portable phosphating hydrogen detector of SKYEAGLEE brand. The instrument adopts EFM ultra-low power consumption 32-bit ARM processor and imported High Accuracy Electrochemical sensor, combined with High Accuracy low temperature drift amplifier and stable power processing circuit to ensure fast detection, accurate measurement, stability and good Repeatability. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, built-in micro sampling pump, and adopts pump-suction detection method, which is suitable for gas concentration monitoring and alarm in various environments.
1. Imported High Accuracy Electrochemical sensor to ensure detection accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Measurement Stability. 3. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Built-in long-life imported micro sampling pump, support low, medium and high adjustment to clean the gas path. 6. Meet the explosion-proof qualification certification, Explosion-proof level is Exia II CT4, the shell adopts anti-skid, waterproof, dustproof and explosion-proof two-color mold design. 7. Support USB interface for high-speed data transmission, and print data can be downloaded. 8. With self-calibration, zero-point calibration, multi-point calibration, temperature and pressure compensation functions. 9. Provide one-click factory reset, self-programming to set alarm parameters, STEL and TWA functions. 10. Support the usual detection and patrol two detection modes, with automatic cleaning gas circuit and fault prompt function.
The detector is based on the principle of Electrochemical sensor. The sensor converts the concentration of phosphating hydrogen gas in the environment into an electrical signal, amplifies and processes the signal through the built-in High Accuracy low temperature drift amplifier and stable power processing circuit, and finally calculates and displays the concentration value by the 32-bit ARM processor. The instrument adopts the pump-suction Sampling method, and the gas is sucked into the gas path through the built-in micro-pump to ensure fast Response and accurate measurement.
Environment monitoring, confined space operation, industrial safety, chemical production, warehousing and logistics, emergency rescue
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on and wait about 30 seconds for the warm-up to complete. 2. Select detection mode: Select normal detection mode or patrol mode through the menu. 3. Set the sampling pump gear: according to the detection needs, adjust the sampling pump to low, medium or high level. 4. Detection: The sampling tube is placed in the environment to be tested, and the instrument automatically displays the real-time concentration value. 5. Data viewing and export: View historical data through the menu, and use the USB interface to connect to the computer to export or print data. 6. Calibration and settings: Regular use of self-calibration, zero or multi-point calibration functions, alarm parameters, STEL/TWA, etc. can be set in the menu. 7. Shutdown: After the detection is completed, press the power button to shut down.
• Before use, make sure that the instrument is fully charged and work at the Ambient Temperature (-30~ 50 ° C) and Humidity (10~ 95% RH without condensation) specified in the instructions. • Avoid use in environments with strong electromagnetic interference, high concentrations of corrosion gases or dust to prevent damage to the Sensor. • Sensor calibration is performed regularly to ensure measurement accuracy. If the calibration is prompted to expire or lose effect, it will be dealt with in time. • The sampling pump has an automatic cleaning function, but it is recommended to manually clean the air passage after long-term use to prevent blockage. • Instruments are designed to be explosion-proof, but must not be disassembled or modified in hazardous locations beyond the Explosion-proof level. Store in a drying and cool place to avoid high temperature (over 70 ° C) or low temperature (below -30 ° C) environment. • If there is a fault prompt, please refer to the instructions or contact a professional maintenance personnel, and do not disassemble it yourself. When replacing the Sensor or Battery, make sure the instrument is turned off and original parts are used.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.