Please contact customer service
Adopt pump-suction third-gear sampling, built-in micro-pump to automatically clean the air circuit. Equipped with 3.5-inch TFT color screen to display trend chart, support 200,000 groups of Data storage and USB export. With temperature and pressure compensation, Response Time ≤ 10 seconds, Explosion-proof level Exia II CT4.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037105
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-H2-Y/2000 Portable Hydrogen Detector is a Handheld Gas detection device using pump-suction detection mode. The instrument applies EFM ultra-low power consumption 32-bit ARM processor, and is equipped with professional imported Electrochemical sensor, combined with High Accuracy low temperature drift amplifier and stable power processing circuit, to ensure the detection of fast, accurate, Stability and good Repeatability. The instrument is equipped with a 3.5-inch full-color TFT display, which supports Chinese and English graphic menu operation, which is convenient for users to use.
1. High Accuracy Electrochemical sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit. 3. Equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store 300,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, and print data can be downloaded. 6. Built-in long-life imported micro sampling pump, adjust the cleaning gas path through three gears of low, medium and high. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration function. 10. With temperature and pressure compensation function. 11. With one-click factory reset function. 12. The gas concentration unit can be quickly switched between LEL and% LEL. 13. With self-programming function, alarm parameters, STEL and TWA function parameters can be set. 14. Provide two detection modes: normal detection and patrol. 15. The detection gas circuit has an automatic cleaning function, which can automatically prompt instrument failure, Sensor calibration expiration and failure.
The Portable hydrogen detector uses the pump-suction Sampling method, which draws environment gases into the instrument through a built-in micro-sampling pump. The gas comes into contact with the built-in imported Electrochemical sensor, which converts the hydrogen concentration signal into an electrical signal. The electrical signal is amplified and processed by a High Accuracy cryogenic bleaching amplifier and a stable power processing circuit, and then operationally analyzed by a 32-bit ARM processor. Finally, the hydrogen concentration value is displayed on the screen in real time, and an alarm is triggered when the concentration exceeds the standard.
It is suitable for environments or confined spaces where hydrogen concentration needs to be monitored, Petrochemicals, power, semiconductor manufacturing, laboratories, emergency rescue and other fields.
Explosion-proof standard: Exia ⅱ CT4
1. Turn on and warm up for about 30 seconds. 2. Select the detection mode (usually detection mode or patrol mode) through the Chinese and English graphic menus. 3. Set alarm parameters, STEL/TWA parameters or Unit switching through the menu as required. 4. According to the detection environment, select the appropriate sampling pump speed (low, medium and high) through the gear key. 5. Extend the sampling tube into the area to be tested for detection, and observe the real-time concentration, MAX Maximum, STEL and TWA values displayed on the screen. 6. After the test is completed, you can use the USB interface to connect to the computer to download or print the stored data. 7. Regularly perform zero or multi-point calibration through the menu to maintain accuracy.
• Do not use under conditions exceeding the Operating Ambient Temperature (-30~ 50 ° C) or Humidity (10~ 95% RH without condensation). Do not use in an environment with an air pressure lower than 86kpa or higher than 106kpa. The instrument is explosion-proof, but it is still necessary to avoid unnecessary use in extremely dangerous environments. • Sensor service life is about 3 years, you need to pay attention to the calibration prompt and replace it in time. • After use or when not in use for a long time, it is recommended to clean the gas path. When performing calibration operations, ensure that the correct standard gas is used and carried out in a safe environment. • Avoid strong impact or immersion in liquids. • When storing, place in a drying environment of -30~ 70 ° C.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.