Using Pump Suction Sampling and Imported Thermal Conductivity Sensor, Range 0-100% Vol, Response Time ≤ 10 seconds. With explosion-proof design, Data storage and self-cleaning function, it is suitable for fast and accurate detection in various environments.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037109
Service :The delivery and service By NBCLab.Com
SK/MIC-800-H2-Y/100% is a Portable hydrogen detector of SKYEAGLEE brand. The instrument adopts imported catalytic combustion Sensor and professional circuit design, combined with 32-bit ARM processor, to achieve fast, accurate and stable hydrogen concentration detection. The instrument is equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphic menu operation, and has a built-in micro sampling pump. It is a pump suction handheld detection device with comprehensive functions and convenient operation.
1. Imported High Accuracy Sensor to ensure measurement accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Long-term Stability. 3. Equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store 200,000 sets of data, and the storage interval is adjustable. 5. Provide USB interface for high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high adjustment to clean the gas path. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. Adopt non-slip, waterproof, dustproof, explosion-proof two-color mold shell design. 9. With self-calibration, zero-point calibration, multi-point calibration function. 10. With temperature and pressure compensation function, adapt to different environments. 11. With a key to restore factory settings, gas concentration unit fast switching, self-programming alarm parameters, STEL and TWA functions. 12. Support the usual detection and patrol two detection modes, with automatic cleaning gas circuit and fault prompt function.
The Portable hydrogen detector uses the pump-suction Sampling method, which draws environment gases into the instrument through a built-in micro-sampling pump. The gas contacts an imported catalytic combustion Sensor at the core of the instrument, which converts the hydrogen concentration signal into an electrical signal. The electrical signal is amplified and processed by a High Accuracy cryogenic drift amplifier and a stable power processing circuit, and finally the hydrogen concentration value is calculated and displayed by a 32-bit ARM processor. The instrument has temperature and pressure compensation to correct for the impact of environmental factors on measurement results.
Environment Monitoring, Confined Space Operation Safety Testing, Industrial Process Control, Emergency Response, Laboratory Safety
ExiaⅡCT4
1. Turn on and warm up for about 30 seconds. 2. Select the detection mode (usually detection mode or patrol mode) as needed. 3. Set alarm parameters, STEL/TWA values, etc. through the menu (optional). 4. Place the sampling tube in the area to be tested, and the instrument inhales the gas through the built-in pump for detection. 5. Real-time reading of hydrogen concentration, MAX Maximum, STEL, TWA and other data through a 3.5-inch color screen. 6. After the test is completed, a high-grade pump can be used to clean the gas path. 7. Connect to the computer through the USB interface to download or print the stored test data.
• Please use within the valid period of instrument calibration and calibrate regularly. • Avoid long-term operation in environments with extreme temperatures (below -30 ° C or above 50 ° C) or high Humidity (which may cause condensation). • Pay attention to the Operating Pressure Range of the instrument (86~ 106kPa), exceeding the range may affect the Measurement accuracy. • The instrument has explosion-proof characteristics, but it still needs to be used within the applicable area of the specified Explosion-proof level (Exia II CT4). • After use or when not in use for a long time, it is recommended to clean the gas path. • When performing zero or multi-point calibration, make sure to operate in a clean air or standard gas environment. • Pay attention to the battery level to ensure that the instrument has sufficient power during the inspection process. • Avoid strong impact or soaking of the instrument to prevent damage. • When downloading data, please use the supporting software and follow the operation guide.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.