Imported Electrochemical sensor, Response Time ≤ 10 seconds, accuracy ≤ +/- 3% F.S. With pump-suction three-speed sampling, 200,000 data storage, 3.5-inch TFT color screen display and automatic cleaning gas circuit function.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037112
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-HCN-Y/2000 Portable Hydrogen Cyanide Detector is a professional Handheld device for detecting the concentration of hydrogen cyanide (HCN) gas in the environment. The instrument adopts imported High Accuracy Electrochemical sensor, combined with EFM ultra-low power 32-bit ARM processor, with two-stage High Accuracy low temperature drift amplifier and stable power processing circuit to ensure fast detection, accurate measurement, Good Stability and High Repeatability. The instrument is equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphic menu operation, built-in long-life micro sampling pump, adopts pump suction detection method, and has the characteristics of explosion-proof, waterproof and dustproof.
1. Imported High Accuracy Electrochemical sensor to ensure detection accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Measurement Stability. 3. Equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, allowing you to download and print data. 6. Built-in long-life imported micro sampling pump, providing low, medium and high adjustable cleaning gas path. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof functions. 9. With self-calibration, zero-point calibration, multi-point calibration functions, and with temperature and pressure compensation. 10. Support one-click factory reset, gas concentration unit can be switched (such as LEL,% LEL). 11. With self-programming function, alarm parameters, STEL and TWA function parameters can be set. 12. Provide two detection modes of normal detection and patrol, and the gas circuit has automatic cleaning function.
The Portable hydrogen cyanide detector uses the pump-suction Sampling method, which actively sucks the environment gas into the instrument through the built-in micro-sampling pump. The gas contacts the built-in imported Electrochemical sensor, and the Sensor converts the concentration signal of hydrogen cyanide gas into an electrical signal. The electrical signal is amplified in two stages by a High Accuracy, Low Temperature Drift amplifier, processed by a stable power processing circuit, and finally calculated and analyzed by the EFM ultra-low power 32-bit ARM processor. The real-time gas concentration value is displayed on the screen, and an alarm is triggered when the concentration exceeds the standard.
Environment Monitoring, Confined Space Operations, Industrial Safety, Emergency Response, Chemical Production
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select normal detection mode or patrol mode through the menu. 3. Set the sampling pump gear: according to the detection needs, select the low, medium or high Sampling flow rate. 4. Detection: The sampling tube is inserted into the area to be tested, and the instrument starts to display the hydrogen cyanide concentration in real time. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration and setting: zero-point calibration, multi-point calibration or setting alarm parameters through self-programming function as needed. 7. Shutdown: After the detection is completed, press the power button for a long time to shut down.
* Please read the instructions carefully before use to ensure that it is used within the instrument range (0-2000ppm) and the allowable working environment (temperature -30~ 50 ° C, Humidity 10~ 95% RH without condensation). * The instrument is designed to be explosion-proof (Exia II CT4), but should be avoided in hazardous locations beyond the explosion-proof level. * Regularly calibrate the Sensor to ensure detection accuracy, and the instrument will prompt when the Sensor calibration expires or fails. * The sampling pump has an automatic cleaning function, but it is still necessary to pay attention to air cleaning after long-term use. Avoid strong impacts or drops on the instrument to avoid damaging internal precision components. * The data storage capacity is 300,000 group, pay attention to regularly export data to avoid insufficient storage space. * The instrument has a built-in lithium battery, please use the matching charger to charge and avoid charging or storing in extreme temperatures. When the instrument issues a malfunction, low power or over-limit alarm, it should be dealt with promptly.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.