Adopt pump-suction three-speed sampling, built-in long-life micro-pump, Response Time ≤ 10 seconds, accuracy ≤ +/- 3% F.S. With explosion-proof, waterproof, dust-proof shell, support temperature and pressure compensation, with self-calibration and Data storage functions.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037113
Service :The delivery and service By NBCLab.Com
The SK/MIC-800-HCN-Y/5000 Portable Hydrogen Cyanide Detector is a Handheld Gas detection device under the SKYEAGLEE brand. The instrument adopts a pump-suction detection method with a built-in long-life imported micro sampling pump, which can quickly detect the concentration of hydrogen cyanide (HCN) gas in the environment and provide an alarm. The instrument uses EFM ultra-low power 32-bit ARM processor, equipped with professional imported Electrochemical sensors, combined with High Accuracy low temperature drift amplifier and stable power processing circuit to ensure the detection of Rapidity, Accuracy, Stability and Good Repeatability. Equipped with a 3.5-inch full-color TFT display, it supports Chinese and English graphic menu operations, and has various functions such as Data storage and USB data transmission.
1. Imported High Accuracy Electrochemical sensor to ensure accurate measurement. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to ensure stable performance. 3. Equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Provide USB interface for high-speed data transmission, support data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high adjustment to clean the gas path. 7. Passed the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration functions, and with temperature and pressure compensation. 10. Support one-button factory reset, gas concentration unit can be quickly switched, and has self-programmed alarm parameters, STEL and TWA functions. 11. Provide the usual detection and patrol two detection modes, the gas circuit has automatic cleaning function, can automatically prompt the fault and Sensor status.
The Portable hydrogen cyanide detector uses a pump-suction Sampling method to actively suck the environment gas into the detection gas chamber through a built-in micro-sampling pump. The hydrogen cyanide (HCN) molecules in the gas react with the imported Electrochemical sensor inside the instrument to generate an electrical signal proportional to the gas concentration. The signal is amplified by a High Accuracy, low temperature drift amplifier, and then performed by a 32-bit ARM processor for analog-to-digital conversion, temperature and pressure compensation, and Data analysis. Finally, the real-time gas concentration value is displayed on the screen. When the concentration exceeds the preset alarm value, the instrument will trigger an audible and visual alarm.
Environment monitoring, confined space operation, industrial safety, emergency testing, chemical production, laboratory
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument needs to be preheated for about 30 seconds. 2. Select detection mode: Select "normal detection mode" or "patrol mode" through the menu. 3. Set the sampling pump gear: according to the detection needs, select the low, medium or high Sampling flow rate. 4. Detection: The sampling tube is inserted into the area to be tested, and the instrument screen will display the hydrogen cyanide concentration in real time. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration and settings: According to needs, zero-point calibration, multi-point calibration or alarm parameters are set through the menu. 7. Shutdown: After the detection is completed, press the power button for a long time to shut down.
* Please read the manual before use to ensure that it is used within the instrument range (0-5000ppm) and the allowable working environment (temperature -30~ 50 ° C, Humidity 10~ 95% RH without condensation). * Avoid use in environments containing substances such as silica gel, silicate, lead, etc. that may poison or inhibit the Sensor. Periodically calibrate the instrument to ensure detection accuracy. * The instrument is explosion-proof, but it is still necessary to avoid disassembly or charging in dangerous places beyond the explosion-proof level. * The sampling tube should be kept clean and open to avoid clogging affecting the test results. When the instrument alarms, it should be evacuated to a safe area immediately and appropriate measures should be taken. * When not in use for a long time, please shut down and store in a drying environment. * It is forbidden to use corrosion liquid to clean the instrument shell. * The built-in Sensor life of the instrument is about 3 years, and it needs to be replaced by a professional when it expires.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.