Please contact customer service
Adopt pump suction sampling, equipped with three-speed Flow rate adjustment. Built-in imported Electrochemical sensor, high detection accuracy, fast Response Time. With explosion-proof certification, suitable for hazardous environments. Support Data storage and USB transmission, with temperature and pressure compensation functions.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037123
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-HBR-Y/400 Portable Hydrogen Bromide Detector is a Handheld Gas detection device. The instrument adopts imported Electrochemical sensor, combined with EFM ultra-low power consumption 32-bit ARM processor, High Accuracy low temperature drift amplifier and stable power processing circuit, which ensures the detection of rapidity, accuracy, Stability and good Repeatability. Equipped with 3.5 inch full color TFT screen, supports Chinese and English graphic menu operation, built-in micro sampling pump, adopts pump suction detection method, suitable for monitoring the concentration of hydrogen bromide gas in the environment or confined space and alarming.
1. High Accuracy Electrochemical sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and stable power processing circuit to ensure accurate and stable measurement. 3.3.5-Inch TFT full-color display, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Equipped with USB interface, supports high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high gear adjustment to clean the gas path. 7. Passed the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. Adopt non-slip, waterproof, dustproof and explosion-proof two-color mold shell. 9. With self-calibration, zero-point calibration, multi-point calibration function. 10. With temperature and pressure compensation function, adapt to different environments. 11. Support one-click factory reset. 12. With self-programming function, alarm parameters, STEL and TWA function parameters can be set. 13. Provide two detection modes: normal detection and patrol. 14. The detection gas circuit has an automatic cleaning function, and automatically prompts instrument failure, Sensor calibration expiration and failure.
The Portable hydrogen bromide detector works based on the principle of Electrochemical sensor. The electrolysis liquid in the Sensor undergoes oxidation and reduction reaction with the target gas (hydrogen bromide), generating an electrical signal proportional to the gas concentration. The weak signal is amplified and processed by the built-in two-stage High Accuracy low temperature drift amplifier of the instrument, and then the 32-bit ARM processor performs data operation, temperature and pressure compensation. Finally, the accurate concentration value is displayed on the screen, and an alarm is triggered when the concentration exceeds the standard.
Environment monitoring, confined space operation safety inspection, industrial process control, emergency accident handling, occupational health protection
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select normal detection mode or patrol mode through the menu. 3. Set the sampling pump gear: according to the detection needs, select the low, medium or high Sampling flow rate. 4. Detection: The sampling tube is inserted into the area to be measured, and the instrument automatically extracts air and displays real-time concentration. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration: Regularly perform zero-point calibration or multi-point calibration through the menu to ensure accuracy. 7. Alarm settings: Set the required Alarm threshold, STEL and TWA parameters through the self-programming function.
• Please read the instructions carefully before use and perform boot self-test in a safe environment. • Instruments need to be calibrated regularly to ensure detection accuracy and avoid using expired or failed Sensors. • Do not use under conditions exceeding the Operating Ambient Temperature (-30~ 50 ° C) and Humidity (10~ 95% RH without condensation). • Pay attention to the Operating Pressure Range of the instrument (86~ 106kpa) and avoid using it under extreme air pressure. • The instrument is of explosion-proof design (Exia II CT4), but it is still necessary to avoid disassembly or charging in hazardous locations beyond the explosion-proof level. • When using the sampling pump, select the appropriate gear according to the cleanliness of the environment, and use the high-grade position to clean the air path after testing. • Avoid strong impact or immersion of the instrument in liquids to prevent damage. • When the instrument issues a fault, Sensor expiration or low battery alarm, it should be dealt with in time. • When not in use for a long time, please store at the recommended storage temperature (-30~ 70 ° C) and charge it regularly for maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
