Please contact customer service
Imported Electrochemical sensor, range 0-200ppm, resolution 0.1ppm, Response Time ≤ 10 seconds. With explosion-proof design, pump-suction three-speed sampling, temperature and pressure compensation, and 300,000 data storage capabilities.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037128
Service :The delivery and service By NBCLab.Com
SK/MIC-800-HCL-Y/200 is a Portable Hydrogen Chloride Detector by SKYEAGLEE brand. The instrument adopts pump-suction Sampling method, applies EFM ultra-low power consumption 32-bit ARM processor and imported High Accuracy Electrochemical sensor, combined with High Accuracy low temperature drift amplifier and stable power processing circuit to ensure fast detection, accurate measurement and good Stability. The instrument is equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, and has various functions such as Data storage, USB data transmission, self-calibration, temperature and pressure compensation. The shell adopts a two-color mode design that is anti-skid, waterproof, dustproof and explosion-proof.
1. High Accuracy Electrochemical sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Accurate and Stable Measurement. 3. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store 300,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, and print data can be downloaded. 6. Built-in long-life imported micro sampling pump, support low, medium and high adjustment to clean the gas path. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration function. 10. With temperature and pressure compensation function, adapt to different environments. 11. With a key to restore factory settings, self-programming alarm parameters, STEL and TWA functions. 12. Support the usual detection and patrol two detection modes, the gas circuit has automatic cleaning function.
The Portable Hydrogen Chloride Detector uses the pump-suction Sampling method, which draws environment gases into the detection gas path through a built-in micro-sampling pump. The gas comes into contact with an imported Electrochemical sensor inside the instrument, which converts the concentration signal of the hydrogen chloride gas into an electrical signal. The electrical signal is amplified by a High Accuracy, Low Temperature Drift amplifier, processed by a stable power processing circuit, and finally calculated and displayed by the core processor based on the EFM ultra-low power 32-bit ARM. The instrument has temperature and pressure compensation to correct for the impact of environmental factors on the measurement results.
Environment monitoring, confined space operation safety inspection, industrial process control, emergency accident handling, occupational health and safety
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select "normal detection mode" or "patrol mode" through the menu. 3. Set the sampling pump gear: select the low, medium or high position as needed for sampling and cleaning the gas path. 4. Detection: The sampling tube is placed in the environment to be tested, and the instrument displays the hydrogen chloride concentration value, STEL, TWA and MAX Maximum in real time. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration and settings: zero-point calibration, multi-point calibration or self-programming alarm parameters through the menu. 7. Shutdown: After the detection is completed, press the power button to shut down.
* Please make sure that the instrument is fully charged before use, and use it within the range of Ambient Temperature (-30~ 50 ° C) and Humidity (10~ 95% RH without condensation) specified in the manual. * Avoid long-term use in environments containing substances such as silica gel, silicate, lead, etc. that may poison the Sensor. * The instrument has an automatic fault prompt function, and should be dealt with in time when a fault occurs, Sensor calibration expires or fails to prompt. * When performing calibration operations, a standard gas of known concentration should be used and zero-point calibration should be carried out in a clean air environment. * The instrument is designed to be explosion-proof, but the battery must not be removed or replaced in hazardous locations beyond the explosion-proof level. * Regularly use the automatic cleaning function of the instrument or manually adjust the pump gear to clean the sampling gas path to ensure the accuracy of detection. * When not in use for a long time, it should be shut down and stored in a drying environment. Temperature range is -30~ 70 ℃. * Do not use corrosion cleaning agents to wipe the instrument case. * Instrument readings are for reference only, if there is any doubt about the measurement results, please use standard gas for verification. * When replacing Sensors or undergoing major repairs, please contact a professional for operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.