Using pump suction sampling and imported Electrochemical sensor, Response Time ≤ 10 seconds, accuracy ≤ +/- 3% F.S. With 3.5-inch color screen display, 200,000 data storage, temperature and pressure compensation functions, the shell is non-slip, waterproof, dustproof and explosion-proof.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037132
Service :The delivery and service By NBCLab.Com
SK/MIC-800-HF-Y/10 Portable Hydrogen Fluoride Detector is a Handheld Gas detection device launched by SKYEAGLEE, which is dedicated to detecting hydrogen fluoride (HF) gas concentration in the environment. The instrument adopts imported High Accuracy Electrochemical sensor, combined with advanced circuit design and data processing technology to ensure fast detection, accurate measurement and stable performance. The instrument is equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphic menu operation, and has a built-in micro sampling pump, which is suitable for pump suction detection.
1. Imported High Accuracy Electrochemical sensors are used to ensure detection accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Measurement Stability. 3. Equipped with a 3.5-inch full-color TFT display, it supports Chinese and English graphical menus and real-time detection of trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Provide a USB interface for high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high adjustment to clean the gas path. 7, through the explosion-proof certification, Explosion-proof level is Exia II CT4, the shell adopts anti-skid, waterproof, dustproof, explosion-proof two-color mold design. 8. It has the functions of self-calibration, zero-point calibration, multi-point calibration, and supports temperature and pressure compensation. 9. Provide one-key factory reset, gas concentration Unit switch, self-programming alarm parameters and STEL/TWA function. 10, support the usual detection and patrol two detection modes, with automatic cleaning gas circuit, fault self-diagnosis and Sensor status prompt function.
The detector works based on the principle of Electrochemical sensor. The electrolysis liquid in the Sensor undergoes oxidation and reduction reaction with the target gas (hydrogen fluoride), generating an electrical signal proportional to the gas concentration. The weak signal is amplified by the built-in two-stage High Accuracy and low temperature drift amplifier of the instrument, and then data processing and compensation are carried out through a stable power processing circuit and a 32-bit ARM processor. Finally, the gas concentration value is displayed on the screen in real time, and the alarm and data recording can be carried out according to the settings.
Chemical production, environment monitoring, emergency rescue, confined space operation, industrial safety inspection
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select mode: Select the usual detection mode or patrol mode through the menu. 3. Set parameters: Set alarm values, STEL, TWA and other parameters through self-programming functions as required. 4. Start detection: The sampling tube is inserted into the area to be tested, and the instrument is detected by built-in pump suction sampling. 5. Data viewing: View gas concentration, MAX Maximum, STEL, TWA and other information and trend charts in real time on the screen. 6. Data management: Connect to a computer through a USB interface to download or print stored historical data. 7. Calibration and maintenance: Regularly use standard gas for zero-point calibration or multi-point calibration to maintain instrument accuracy.
* Please read the instructions carefully before use, and perform boot and self-test in a safe environment. The instrument is designed to detect hydrogen fluoride gases. Do not use it to detect unspecified gases. * Avoid long-term use in extreme temperatures (below -30 ° C or above 50 ° C) or high Humidity (above 95% RH and condensing) environments. * Regularly calibrate the Sensor to ensure detection accuracy, and the instrument will prompt when the calibration expires or fails. * The instrument has an explosion-proof design, but still needs to avoid disassembly or impact in hazardous locations beyond the explosion-proof level. * The sampling pump has an automatic gas cleaning function, but it is recommended to follow the instructions for maintenance after long-term use. * Data storage space is limited, please export data periodically to prevent overwriting. If the instrument malfunctions, stop using it immediately and contact a professional for maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.