Pump suction sampling and infrared NDIR Sensor, range 0~ 1000ppm, resolution 0.1ppm, accuracy ≤ 3% F.S., Response Time ≤ 10 seconds. With 3.5 inch full color screen, 200,000 data storage, USB data transmission and automatic cleaning function, Explosion-proof level Exia II CT4, suitable for harsh environments.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037145
Service :The delivery and service By NBCLab.Com
SK/MIC-800-SF6-Y/1000 is a Portable SF6 detector from SKYEAGLEE brand. The instrument uses EFM ultra-low power 32-bit ARM processor and imported infrared NDIR Sensor, combined with High Accuracy low temperature drift amplifier and stable power processing circuit to ensure fast detection, accurate measurement, stability and good Repeatability. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, and has a built-in micro sampling pump to realize pump suction detection.
1. Imported High Accuracy Infrared NDIR Sensor to detect sulfur hexafluoride gas. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Accurate and Stable Measurement. 3.3.5-Inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. Data storage has powerful functions, can store 300,000 sets of data, and the storage interval is adjustable. 5. The USB interface supports high-speed data transmission and can download print data. 6. Built-in long-life imported micro sampling pump, support low, medium and high three-speed adjustment, with automatic cleaning gas circuit function. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold process, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration function, with temperature and pressure compensation. 10. With two modes of normal detection and patrol, it supports self-programming to set alarm parameters, STEL and TWA functions.
The detector uses a pump-suction Sampling method, and the environment gas is sucked into the detection gas path by a built-in micro-sampling pump. The gas is contacted with the built-in imported infrared NDIR Sensor. The Sensor is based on the principle of non-dispersed infrared to accurately determine the concentration of sulfur hexafluoride gas by detecting the absorption of specific wavelengths of infrared light. The detection signal is processed by a power circuit amplified and stabilized by a High Accuracy cryogenic drift amplifier. It is calculated by a 32-bit ARM processor, compensated for by temperature and pressure. Finally, the concentration value is displayed on the screen in real time, and an alarm is triggered when the standard is exceeded.
Sulfur hexafluoride gas leak detection, power equipment maintenance, confined space operation safety monitoring, environment monitoring, industrial safety inspection
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select normal detection mode or patrol mode through the menu. 3. Set the sampling pump gear: according to the detection needs, select the low, medium or high Sampling flow rate. 4. Detection: The sampling tube is inserted into the area to be measured, and the instrument automatically samples and displays the real-time concentration. 5. View data: You can view real-time data, historical data, STEL, TWA values, and trend graphs through the menu. 6. Data export: Connect to the computer through the USB interface to export the stored test data. 7. Shutdown: After the detection is completed, press the power button for a long time to shut down.
* Please use it within the valid period of instrument calibration, and perform zero and multi-point calibration regularly. * Avoid working in extreme temperatures (below -30 ° C or above 50 ° C) or Humidity (condensing environment) for long periods of time. The instrument has an automatic fault prompt function, and should be dealt with in time when prompted. * The sampling tube should be kept unobstructed to avoid clogging affecting the test results. * The instrument is designed to be explosion-proof, but should not be disassembled or repaired in hazardous locations beyond the Explosion-proof level. * When charging or data transmission, please ensure that the environment is safe and away from the detection gas. * When not in use for a long time, please shut down and store in a drying environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.