Adopt pump-suction sampling and infrared NDIR Sensor, detection range 0-5000ppm, resolution 0.1ppm, Response Time ≤ 10 seconds. With explosion-proof design, 200,000 data storage, TFT color screen display and temperature and pressure compensation functions.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037147
Service :The delivery and service By NBCLab.Com
SK/MIC-800-SF6-Y/5000 is a Portable sulfur hexafluoride detector of SKYEAGLEE brand. The instrument adopts pump-suction detection method, applies EFM ultra-low power consumption 32-bit ARM processor, is equipped with professional imported infrared NDIR Sensor, combined with High Accuracy low temperature drift amplifier and stable power processing circuit to ensure fast detection, accurate measurement, stability and good Repeatability. The instrument is equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, and has functions such as Data storage and USB data transmission. The shell adopts a two-color mode design that is anti-skid, waterproof, dustproof and explosion-proof.
1. Imported High Accuracy Infrared NDIR Sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Accurate and Stable Measurement. 3. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store 300,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, and print data can be downloaded. 6. Built-in long-life imported micro sampling pump, adjust the cleaning gas path through low, medium and high gears. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration functions, support temperature and pressure compensation. 10. It has the functions of one-click factory reset, self-programming to set alarm parameters, STEL and TWA, and supports two modes of normal detection and patrol.
The detector uses the pump-suction Sampling method, and the environment gas is sucked into the detection gas path by the built-in micro-sampling pump. After the gas is pretreated, it reaches the infrared NDIR Sensor at the core. Based on the principle of non-dispersed infrared, the Sensor calculates the gas concentration by measuring the Absorption intensity of sulfur hexafluoride gas to specific wavelengths of infrared light. A 32-bit ARM processor inside the instrument processes the Sensor signal, combining temperature and pressure compensation algorithms, and finally displays the exact concentration value on the screen, and triggers an alarm when the limit is exceeded.
Sulfur hexafluoride gas leak detection, power industry (such as GIS switch station, substation), confined space operation safety monitoring, environment monitoring, industrial process control
ExiaⅡCT4
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select detection mode: Select normal detection mode or patrol mode through the menu. 3. Set the sampling pump gear: according to the detection needs, select the low, medium or high Sampling flow rate. 4. Detection: The sampling tube is inserted into the area to be measured, and the instrument displays the gas concentration in real time. 5. Data viewing and export: You can view historical data through the menu, or connect to a computer through the USB interface to export data. 6. Calibration and setting: zero-point calibration, multi-point calibration or setting alarm parameters through self-programming function as needed. 7. Shutdown: After the detection is completed, press the power button to shut down.
• Please use within the range of Ambient Temperature (-30~ 50 ℃) and Humidity (10~ 95% RH without condensation) specified by the instrument. • Avoid long-term use in strong electromagnetic interference, corrosion gas or high concentration dust environment. • Regularly calibrate the instrument to ensure detection accuracy. • The instrument has the function of automatic cleaning of the gas circuit, but it is recommended to manually clean the sampling pipeline after long-term use. • When charging or data transmission, make sure to use the matching dedicated cable and adapter. • Instruments are designed to be explosion-proof, but must not be disassembled or repaired in hazardous locations beyond the Explosion-proof level. • Pay attention to the service life of the Sensor (about 3 years), and it needs to be replaced in time when it expires. Store in a drying and cool place to avoid high temperature (over 70 ° C) or low temperature (below -30 ° C) environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.