Please contact customer service
Imported PID Light Ion Sensor with high detection accuracy and fast Response Time. With pump suction three-speed sampling, automatic cleaning gas circuit, temperature and pressure compensation functions, support STEL/TWA calculation and large Data storage, explosion-proof and waterproof design to adapt to complex working conditions.
Category : VOC Gas Detector
Brand : Skyeaglee
SKU : NB037155
Service :The delivery and service By NBCLab.Com
SKYEAGLEE SK/MIC-800-VOC-Y/2 Portable VOC detector is a Handheld Gas detection device using pump suction detection mode. The instrument applies EFM ultra-low power consumption 32-bit ARM processor, and is equipped with a professional imported catalytic combustion Sensor (PID photoion principle), combined with High Accuracy low temperature drift amplifier and stable power processing circuit, to ensure fast detection, accurate measurement, stable and Repeatability. The instrument is equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphic menu operation, and has various functions such as Data storage and USB data transmission.
1. Imported High Accuracy Sensor. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit. 3. Equipped with a 3.5-inch full-color TFT screen, supports Chinese and English graphical menus, and provides real-time detection trend analysis charts. 4. With Data storage function, it can store 200,000 sets of data, and the storage interval is adjustable. 5. Support USB interface for high-speed data transmission, and print data can be downloaded. 6. Built-in long-life imported micro sampling pump, adjust the cleaning gas path through the gear. 7. Meet the explosion-proof qualification certification, and the explosion-proof level is Exia II CT4. 8. The shell adopts two-color mold, which has anti-skid, waterproof, dustproof and explosion-proof characteristics. 9. With self-calibration, zero-point calibration, multi-point calibration function. 10. With temperature and pressure compensation function. 11. With one-click factory reset function. 12. The gas concentration unit can be quickly switched between LEL and% LEL. 13. With self-programming function, alarm parameters, STEL and TWA function parameters can be set. 14. Provide two detection modes: normal detection and patrol. 15. The detection gas circuit has an automatic cleaning function, which can automatically prompt instrument failure, Sensor calibration expiration and failure.
The Portable VOC detector uses a pump-suction detection method with a built-in micro-sampling pump to suck the environment gas into the inside of the instrument. The gas contacts the Sensor (according to the model PID light ion principle Sensor), and the Sensor converts the gas concentration signal into an electrical signal. The electrical signal is amplified and processed by a High Accuracy cryogenic drift amplifier and a stable power processing circuit. Finally, the EFM ultra-low power 32-bit ARM processor inside the instrument calculates and displays the real-time gas concentration value. The instrument has temperature and pressure compensation functions to ensure measurement accuracy under different environment conditions.
Monitoring gas concentrations in the environment or confined spaces and alerting
ExiaⅡCT4
1. Boot warm-up (Warm-Up Time about 30 seconds). 2. Select the detection mode (usually detection mode or patrol mode) as needed. 3. Set alarm parameters and STEL/TWA parameters (if required) through the menu. 4. Place the sampling tube in the area to be tested, and the instrument passes the built-in pump suction sampling. 5. Observe the real-time concentration, MAX Maximum, STEL, TWA and other information displayed on the screen. 6. Use the Data storage function to record data (the storage interval is adjustable). 7. Connect to the computer through the USB interface to download or print the stored data. 8. Use self-calibration, zero or multi-point calibration functions to calibrate the instrument (if required). 9. Use the air circuit cleaning function (by adjusting the pump's gear) to clean the air circuit.
• Do not use in environments beyond the range of Operating temperature (-30~ 50 ℃), Humidity (10~ 95% RH without condensation) and Air pressure (86kpa-106kpa). • The instrument has Explosion-proof level Exia II CT4, but still needs to be used in the specified explosion-proof environment. • Pay attention to the service life of the Sensor (about 3 years), and pay attention to the prompt of the instrument about the expiration or failure of the Sensor calibration. • When performing zero or multi-point calibration, it needs to be operated in clean air or standard gas environment. • When using pump suction detection, pay attention to selecting low, medium and high-grade positions according to the situation, and regularly use the automatic cleaning function to maintain the gas path. • Avoid strong impact or immersion of the instrument in liquids, despite its waterproof and dustproof housing. • When not in use for a long time, please store at the specified storage temperature (-30~ 70 ° C). • When downloading or charging data, please ensure that the connection environment is safe. • Before using the one-click factory reset function, please confirm that important data has been backed up, which will clear the user settings.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.