Please contact customer service
Imported High Accuracy Electrochemical sensor, Response Time ≤ 10 seconds, accuracy ≤ +/- 3% F.S. With pump-suction three-speed sampling, 3.5-inch full-color screen display, 200,000 data storage and automatic cleaning gas circuit functions, in line with Exia II CT4 explosion-proof certification.
Category : Gas Detector
Brand : Skyeaglee
SKU : NB037158
Service :The delivery and service By NBCLab.Com
SK/MIC-800-CH2O-Y/10 is a Portable Formaldehyde detector under the SKYEAGLEE brand. The instrument adopts pump-suction detection mode, equipped with imported High Accuracy Electrochemical sensor, combined with EFM ultra-low power 32-bit ARM processor, High Accuracy low temperature drift amplifier and stable power processing circuit, to ensure fast detection, accurate measurement, stability and Repeatability. The instrument is equipped with a 3.5-inch full-color TFT display, supports Chinese and English graphic menu operation, and has a built-in micro sampling pump, which is suitable for formaldehyde concentration monitoring and alarm in various environments.
1. Imported High Accuracy Electrochemical sensor to ensure detection accuracy. 2. Use High Accuracy Low Temperature Drift Amplifier and Stable Power Processing Circuit to Ensure Measurement Stability. 3. Equipped with a 3.5-inch full-color TFT display, it supports Chinese and English graphical menus and real-time detection of trend analysis charts. 4. With Data storage function, it can store up to 300,000 sets of data, and the storage interval is adjustable. 5. Provide USB interface for high-speed data transmission and data download and printing. 6. Built-in long-life imported micro sampling pump, support low, medium and high adjustment to clean the gas path. 7. Pass the explosion-proof qualification certification, Explosion-proof level is Exia II CT4, the shell adopts two-color mold design, with anti-skid, waterproof, dustproof and explosion-proof characteristics. 8. Support self-calibration, zero-point calibration, multi-point calibration functions, and with temperature and pressure compensation. 9. It has one-click factory reset, self-programming alarm parameters, STEL and TWA functions, and two modes of detection and patrol.
The Portable Formaldehyde detector works based on the principle of Electrochemical sensor. The instrument has a miniature sampling pump built into the instrument, which sucks the environment gas into the detection gas path. The formaldehyde molecules in the gas undergo an electrochemistry reaction inside the Sensor, generating an electrical signal proportional to the concentration. The signal is amplified and processed by a High Accuracy low temperature drift amplifier and a stable power processing circuit, and then calculated by a 32-bit ARM processor, temperature and pressure compensation. Finally, the formaldehyde concentration value is displayed on the screen in real time, and an alarm is triggered when it exceeds the standard.
Environment monitoring, confined space testing, industrial safety, indoor air mass assessment, occupational health protection
Explosion-proof certification (Exia ⅱ CT4)
1. Boot warm-up: Press the power button for a long time to turn it on, and the instrument will warm up for about 30 seconds. 2. Select mode: Select the normal detection mode or patrol mode through the menu. 3. Set the sampling pump gear: according to the detection needs, select the low, medium or high Sampling flow rate. 4. Start detection: Place the sampling tube in the area to be tested, and the instrument automatically inhales the gas and displays the real-time concentration. 5. Data viewing and export: You can view historical data, STEL/TWA values through the menu, and use the USB interface to connect to the computer to export data. 6. Calibration and settings: According to the needs, zero-point calibration, multi-point calibration or alarm parameters can be programmed through the menu. 7. Shutdown: After the detection is completed, press the power button to shut down.
* Do not use under conditions exceeding the Operating Ambient Temperature (-30~ 50 ° C) or Humidity (10~ 95% RH without condensation). * Avoid strong impact or immersion of the instrument in liquid to protect its explosion-proof, waterproof and dustproof performance. * Sensor calibration is performed regularly to ensure detection accuracy, and the instrument has a calibration expiration prompt function. * Please check whether the sampling tube is unobstructed before use to ensure that the air path is not blocked. When the instrument alarms, appropriate safety measures should be taken immediately and evacuated to a safe area. When charging or transferring data, please ensure that it is carried out in a safe area. * When not in use for a long time, please store the instrument in a drying, temperature appropriate (-30~ 70 ℃) environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.