$ 396.00Ex works
The series micro motor provides 94N.cm large torque, multi-stage Non-metallic gear transmission realizes low noise and stable operation, supports 100-1400rpm stepless speed regulation and 28L Processing capacity, and is suitable for a variety of special Impellers.
Category : Laboratory Mixer
Brand : HuXi
SKU : NB037305
Service :The delivery and service By NBCLab.Com
HUXI JB90-SH/20030001 digital display constant speed powerbasic stirrer is a liquid mixing and stirring equipment suitable for biological, physical and chemical, cosmetics, health products, food and other experimental fields. The product design is novel, the manufacturing process is professional, the low-speed running torque output is large, the continuous use performance is good, the series micro motor is safe and reliable, the numerical control touch stepless governor is convenient for speed regulation and digital display Rotation speed, the multi-stage Non-metallic gear transmission enhancements make the operation stable and low noise, and the stirringrod special head is easy and flexible to unload. It is an ideal equipment for factories, scientific research institutions, Universities & colleges and medical units.
1. Impellers have a wide range of types, specifications and adaptations; 2. Impeller special rolling head, easy to uninstall and operate; 3. Open rack: media container with wide selectivity, easy mixing and mixing; 4. Instrument specifications are diverse to meet the mixing requirements of different sample capacities and viscosities. 5. Segmental variable speed control: Rotation speed of experimental operation can be selected arbitrarily, with wide application range and convenient speed regulation; 6. Aluminum metal casing ensures mechanical accuracy for long-term use and electrical performance for continuous use; 7. The drive motor adopts a series micro motor with large Power and compact structure, which runs safely and reliably; 8. Novel product design, professional manufacturing process, large torque output at low speed, good continuous use performance; 9. Multi-stage Non-metallic gears are used to transmit force, torque is doubled, running state is stable, and noise is low;
The Stirrer is driven by a series-excited micro-motor and adopts a multi-stage Non-metallic gear transmission booster mechanism to double the torque and achieve stable operation and low noise. The control motion state adopts a numerical control touch stepless governor, which can adjust the Rotation speed arbitrarily and display the running status digitally to ensure correct data collection. The Impeller is fixed by a special tie, and the unloading is simple and flexible, which adapts to a variety of experimental needs.
Biological, physical and chemical, cosmetics, health products, food and other experimental fields, factories, scientific research institutions, Universities & colleges, medical units
1. Select the appropriate Impeller type and specification according to the experimental requirements. 2. Use a special rolling head to install the Impeller to ensure firm fixation; 3. Place the Stirrer on an open rack and select the appropriate media container. 4. Connect the power supply and start the device. 5. Rotation speed is adjusted to the required range by numerical control touch stepless governor; 6. Observe the digital display Rotation speed status and conduct data collection; 7. After the experiment is completed, turn off the power and remove the Impeller for cleaning and maintenance.
• Power supply voltage meets AC 220 V 50 Hz requirements before use; • When installing the Impeller, check whether the special rolling head is firmly fixed to prevent loosening during operation; • Adjust slowly when adjusting the speed to avoid sudden high-speed start damage to the equipment; • Pay attention to the state of the equipment during operation, and immediately stop for inspection if there is any abnormal noise or vibration. • Regularly clean and maintain equipment to ensure that the aluminum casing and mechanical components are in good condition. • Choose the appropriate Impeller type according to the viscosity and capacity of the liquid to avoid overloading. • Pay attention to heat dissipation when the equipment is used continuously to avoid overheating affecting performance; • Non-professionals should not disassemble internal components to prevent damage to the electrical system.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.