Overview
HUXI LED overhead Stirrer (model: RWD50E/20030064) is a laboratory equipment suitable for mixing medium and high viscosity liquids. The product is capable of high load, long continuous operation, outstanding performance, and automatic protection for overload and abnormal conditions to ensure laboratory safety.
Features
1, LED display, Rotation speed can be coarse and fine adjustment, the instrument operation, can also adjust the Rotation speed.
2. The motor starts softly and runs smoothly, effectively preventing sample overflow.
3. The closed enclosure effectively prevents liquid from splashing into the instrument, ensuring the safe operation of the experiment.
4. Configure the Impeller penetration hole, the user does not need to adjust the installation height of the instrument, just adjust the installation position of the stirring rod.
5. Provide a variety of Impellers and brackets to choose from.
Principle
The Stirrer uses a motor to drive the Impeller swirl/spin to mix liquids. The motor uses soft start technology for smooth operation. The device has a through hole design for easy adjustment of the stirring rod position to suit different containers.
Applications
Chemical synthesis, physical and chemical analysis, petrochemical, cosmetics, health products, food, biotechnology
Standards
Protection Rating: IP42
Steps
1. Select the appropriate Impeller according to the experimental requirements and install it.
2. Adjust the stirring rod to the appropriate height through the penetration hole and fix it.
3. Turn on the power supply.
4. Set the required Rotation speed through the LED screen and speed control knob (support coarse and fine adjustment).
5. Start the equipment to stir.
6. After the experiment, turn off the power and clean the equipment.
Notice
• Please make sure to use it at the allowable Ambient Temperature (5~ 40 ° C) and relative humidity (≤ 80%).
• Before use, please confirm that the Power supply voltage (100-240VAC) matches the local power grid.
• Impeller installation needs to be firm to prevent loosening or peeling during operation.
• Do not put your hands or Miscellaneous items near swirling/spinning parts while the equipment is running.
• The device has overload and abnormal protection functions. If it triggers automatic stop and is accompanied by a sound prompt, please check the cause before using it.
• Please disconnect the power supply when cleaning and avoid liquid splashing into the inside of the instrument.
• Please select the appropriate Impeller and Rotation speed according to the liquid viscosity (up to 10000mPa · s) and Processing capacity (up to 20L).
• When the drill chuck clamps the stirring rod, make sure that the rod diameter is within the range of 0.5 to 10mm.