Overview
HUXI RWD100E/20030038 LED overhead Stirrer is a laboratory equipment suitable for mixing medium and high viscosity liquids. This product is capable of high load, long-term continuous work, outstanding performance, and automatic protection for overload and abnormal conditions to ensure laboratory safety.
Features
1. LED screen display, Rotation speed can be coarse and fine-tuned, and Rotation speed can also be adjusted during the operation of the instrument.
2. Motor soft start, smooth operation, effectively prevent sample overflow.
3. The closed enclosure effectively prevents liquid from splashing into the instrument, ensuring the safe operation of the experiment.
4. Configure the Impeller penetration hole, the user does not need to adjust the installation height of the instrument, just adjust the installation position of the stirring rod.
5. Provide a variety of Impellers and brackets to choose from.
Principle
Impeller swirl/spin motor is used to mix medium and high viscosity liquids. The motor has a soft start function, smooth operation, and can precisely control the stirring speed through stepless speed regulation to adapt to different viscosity liquids and processing needs.
Applications
Chemical synthesis, physical and chemical analysis, petrochemical, cosmetics, health products, food, biotechnology
Standards
Protection Rating: IP42
Steps
1. Select the appropriate Impeller according to the characteristics of the liquid to be stirred.
2. Install the stirring rod through the penetration hole on the top of the instrument and fix it with a wrench chuck.
3. Turn on the power supply.
4. Rotation speed coarse or fine adjustment through the control panel, set the required Rotation speed.
5. Start the equipment to start stirring, and the Rotation speed can be adjusted at any time as needed during operation.
6. After the experiment, turn off the power, remove and clean the Impeller.
Notice
• Please make sure to use it at the allowable Ambient Temperature (5~ 40 ° C) and relative humidity (≤ 80%).
• Before use, please confirm that the Power supply voltage (100-240VAC) matches the local power grid.
• Impeller clamping diameter range is 0.5~ 10mm, please do not use beyond the range.
• The device has an overload protection function. When the trigger protection automatically stops and an audible prompt is issued, please check the load condition.
• Pay attention to the non-slip pad at the bottom of the instrument to ensure that the equipment is placed smoothly.
• Do not let liquids splash into the inside of the instrument to ensure the safety and service life of the equipment.