Overview
YIHENG BPN-80CRH Co2 incubator combines more than ten years of design and manufacturing experience, representing the development trend of Co2 incubator. Using imported infrared CO2 Sensor, the control accuracy is accurate and stable, and it is not affected by temperature and Humidity.
Features
1. Faster CO2 concentration recovery speed, after opening the door for 30 seconds, the door can be restored to 5% in less than 5 minutes, and the set CO2 concentration can be restored to 37 ° C in less than 10 minutes
2. Equipped with Microbial Effective Filter, the filtrating efficiency of particles with a diameter of ≥ 0.3μm is as high as 99.99%
3. Door temperature heating system, effectively prevent Glass door condensation
4. Automatic control of circulating fan speed to avoid sample volatilization
5. HEPA Effective Filter, the air mass in the box can be restored to 100 clean level after the door is closed for 5 minutes
6. Stackable placement (two layers), large LCD screen
7. Independent temperature limit alarm system, with temperature, CO2 concentration, door opening time is too long and other alarm functions
8.90 ℃ high temperature heating and humidity sterilizing system, effectively eliminate all kinds of microbial pollution
9. Data recording and fault diagnosis display function (optional)
Principle
Imported infrared CO2 Sensor is used to monitor carbon dioxide gas, which is not affected by external temperature Humidity fluctuations. Equipped with Microbial Filter and HEPA Filter to effectively filtrate bacteria and dust particles. Prevent condensation through door heating system, and automatically adjust the speed of circulating fan to maintain a suitable cell growth environment.
Applications
Cell fostering, Microbial experiments, Biomedical research
Steps
1. Turn on the power supply AC220V/50Hz
2. Set the temperature and CO2 concentration parameters through the large LCD screen
3. Put in the experimental sample
4. Close the door, the system automatically restore the setting environment
5. Regularly carry out 90 ℃ high temperature heating and humidity sterilization
6. Download data through RS485 port (optional)
Notice
• Ambient Temperature should be kept at + 5~ 30 ℃
• Avoid frequent opening and closing of doors affecting CO2 concentration Stability
• Regularly check HEPA Filter status
• Pay attention to alarm prompts and deal with abnormal situations in a timely manner
• Use a dedicated carbon dioxide pressure reducing valve
• Keep the box clean to prevent microbial contamination